AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (5.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Just Accepted

Experimental study on the heat transfer characteristics of bottom jet impingement boiling

Fangzhou Song1,2, Zhengze Wu1,2, Xinyuan Qian2( ), Yuntao Song2( ), Siqing Feng3, Xuebing Peng2, Kun Lu2

1 Science Island Branch, Graduate School of the University of Science and Technology of China, Hefei 230026, China

2 Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

3 School of Automotive Engineering, Anhui University of Applied Technology, Hefei 230011, China

Show Author Information

Abstract

The thermal performance of a divertor is critical for tokamak operational safety. While the combination of jet impingement and boiling could enhance heat transfer in compact spaces, bottom jet configurations required by divertor geometry remain poorly studied. In this paper, heat transfer experiments on flat plates and pin-finned surfaces are conducted using a visual experiment platform. In the experiment, the jet-to-surface distance (H) is set at 1.6–14 mm, and the flow rate (Q) is 200–500 mL/min, while a high-speed camera is employed to capture jet impingement boiling images for auxiliary analysis. The results show that increasing Q from 200 to 500 mL/min enhances the single-phase heat transfer coefficients (h) by 82.1%–189.3% (flat plate surface) and 79%–141.5% (pin-finned surface) across H values. The critical heat flux (CHF) improvements can reach 84.3% for the flat plate surface and 76.2% for the pin-finned surface, primarily due to enhanced coolant replenishment. Reducing H from 14 to 1.6 mm further improves single-phase h by 39.8%–122% (flat plate surface) and 75.2%–136.2% (pin-finned surface), but excessive H reduction may degrade boiling on flat plate surfaces due to vapor confinement—an effect mitigated by pin-fins. Moreover, the pin-finned surface demonstrates superior performance with over twice the heat flux (q) at identical superheat, along with average enhancements of 16.5% in CHF and 33.8% in maximum h, attributed to enhanced capillary wetting and optimized bubble dynamics. Finally, correlations are established to reliably predict the heat transfer performance across the investigated parameter range. These findings provide  guidance for high-heat-load applications such as divertor thermal management systems. 

Electronic Supplementary Material

Download File(s)
ECMF0288-ESM.rar (32.4 MB)

References

【1】
【1】
 
 
Experimental and Computational Multiphase Flow

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Song F, Wu Z, Qian X, et al. Experimental study on the heat transfer characteristics of bottom jet impingement boiling. Experimental and Computational Multiphase Flow, 2026, https://doi.org/10.1007/s42757-026-0288-z

352

Views

14

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 15 September 2025
Revised: 05 January 2026
Accepted: 13 January 2026
Available online: 18 May 2026

© Tsinghua University Press 2026.