AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Investigation of operational limit of a pulsating heat pipe by estimating local heat transfer

Naoko Iwata, Fabio Bozzoli( )
Department of Engineering and Architecture, University of Parma, Parma 43124, Italy
Show Author Information

Abstract

How pulsating heat pipes (PHPs) reach their operational limit has not yet been fully understood. This study aims to provide a complete picture of the termination mechanism of the self-oscillation of vapor and liquid. Experimental studies on a 10-turn PHP with HFC-134a were conducted and the filling ratio (FR) was from 20% to 80%. The thermo-fluid behavior in the PHP was investigated by temperature measurements with a high-resolution and high-speed infrared camera and estimation of fluid-to-wall heat flux distributions by solving inverse heat conduction problems. The results suggested that the PHP, increasing heat load, reached the operational limit due to different mechanisms depending on the filling ratio: at a high FR (80%), the liquid volume ratio increased with the increase of the operating temperature, resulting in the compressed liquid phase. At a low FR (20%), when a large amount of heat was applied, the fluid in the evaporator dried out and became a superheated vapor. The PHP with an optimum FR (50%) transferred the maximum heat under the same evaporator temperature, as the fluid in the PHP was able to keep the saturated two-phase state until the evaporator temperature exceeded the critical temperature.

Graphical Abstract

References

【1】
【1】
 
 
Experimental and Computational Multiphase Flow
Pages 265-276

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Iwata N, Bozzoli F. Investigation of operational limit of a pulsating heat pipe by estimating local heat transfer. Experimental and Computational Multiphase Flow, 2024, 6(3): 265-276. https://doi.org/10.1007/s42757-023-0179-5

1817

Views

10

Crossref

8

Web of Science

8

Scopus

Received: 27 August 2023
Revised: 08 November 2023
Accepted: 13 November 2023
Published: 14 March 2024
© The Author(s) 2024

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.