AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Numerical study on thermal-hydraulic characteristics of petal-shaped fuel rod assembly under cosine heating conditions

Zequan Huang1, Wenchao Zhang1,2( ), Jianchuang Sun1, Guangyuan Jin1, Jun Cui3, Weihua Cai1( )
Laboratory of Thermo-fluid Science and Nuclear Engineering, School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132012, China
Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084, China
China Nuclear Power Technology Research Institute Co., Ltd., Shenzhen 518031, China
Show Author Information

Abstract

Petal-shaped fuel rod assemblies are characterized by their compact structure and high power density, making them highly promising for application in small-scale reactors. This study uses the Realizable k–ε turbulence model, Eulerian two-fluid model, and wall boiling model to investigate the spatial evolution of thermal-hydraulic characteristics in 2 × 2 petal-shaped fuel rod assembly under cosine heating conditions. The onset of nucleate boiling (ONB) and critical heat flux (CHF) are determined, and based on these, the flow field, temperature field, void fraction, and heat transfer characteristics in both single-phase and subcooled boiling regions are analyzed. Results show that in the single-phase region, fuel temperature is low and heat transfer coefficient fluctuates periodically at a low level. In the subcooled boiling region, void fraction distribution follows a peak-like pattern along the axial direction due to cosine heating influence. Vapor phase generation leads to the increased fluctuation amplitude of coolant transverse flow, evaporation heat flux gradually dominates, leading to a significant increase in the heat transfer capacity of the rod bundle channel. CHF occurs at the inner concave arc of the fuel rod slightly above the channel center, and void fraction peaks at ZCHF; moreover, the deterioration of heat transfer causes a significant decrease in heat transfer coefficient.

References

【1】
【1】
 
 
Experimental and Computational Multiphase Flow
Pages 97-108

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Huang Z, Zhang W, Sun J, et al. Numerical study on thermal-hydraulic characteristics of petal-shaped fuel rod assembly under cosine heating conditions. Experimental and Computational Multiphase Flow, 2025, 7(1): 97-108. https://doi.org/10.1007/s42757-023-0175-9

893

Views

6

Crossref

7

Web of Science

8

Scopus

Received: 01 June 2023
Revised: 04 August 2023
Accepted: 06 August 2023
Published: 31 March 2025
© Tsinghua University Press 2025