AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

A computational analysis on the impact of multilevel laryngotracheal stenosis on airflow and drug particle dynamics in the upper airway

Raluca E. Gosman1,2, Ryan M. Sicard2, Seth M. Cohen2, Dennis O. Frank-Ito1,2,3,4( )
Duke University School of Medicine, Duke University Medical Center, 40 Duke Medicine Circle, Durham, NC 27708, USA
Department of Head and Neck Surgery & Communication Sciences, Duke University Medical Center, Durham, NC 27708, USA
Computational Biology & Bioinformatics PhD Program, Duke University, Durham, NC 27708, USA
Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA
Show Author Information

Abstract

Laryngotracheal stenosis (LTS) is a type of airway narrowing that is frequently caused by intubation-related trauma. LTS can occur at one or multiple locations in the larynx and/or trachea. This study characterizes airflow dynamics and drug delivery in patients with multilevel stenosis. Two subjects with multilevel stenosis (S1 = glottis + trachea, S2 = glottis + subglottis) and one normal subject were retrospectively selected. Computed tomography scans were used to create subject-specific upper airway models. Computational fluid dynamics modeling was used to simulate airflow at inhalation pressures of 10, 25, and 40 Pa, and orally inhaled drug transport with particle velocities of 1, 5, and 10 m/s, and particle size range of 100 nm–40 µm. Subjects had increased airflow velocity and resistance at stenosis with decreased cross-sectional area (CSA): S1 had the smallest CSA at trachea (0.23 cm2) and resistance = 0.3 Pa·s/mL; S2 had the smallest CSA at glottis (0.44 cm2), and resistance = 0.16 Pa·s/mL. S1 maximal stenotic deposition was 4.15% at trachea; S2 maximal deposition was 2.28% at glottis. Particles of 11–20 µm had the greatest deposition, 13.25% (S1-trachea) and 7.81% (S2-subglottis). Results showed differences in airway resistance and drug delivery between subjects with LTS. Less than 4.2% of orally inhaled particles deposited at stenosis. Particle sizes with most stenotic deposition were 11–20 µm and may not represent typical particle sizes emitted by current-use inhalers.

References

【1】
【1】
 
 
Experimental and Computational Multiphase Flow
Pages 235-246

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Gosman RE, Sicard RM, Cohen SM, et al. A computational analysis on the impact of multilevel laryngotracheal stenosis on airflow and drug particle dynamics in the upper airway. Experimental and Computational Multiphase Flow, 2023, 5(3): 235-246. https://doi.org/10.1007/s42757-022-0151-9

1566

Views

10

Crossref

13

Web of Science

13

Scopus

Received: 22 June 2022
Revised: 31 August 2022
Accepted: 24 November 2022
Published: 18 March 2023
© Tsinghua University Press 2023