Optimal soft early-stop of multi-chiller plants for effective utilization of passive cold storage in buildings

Xiaoyu Lin1, Kui Shan1,2, Hangxin Li1,3, Shengwei Wang1,2,3( )
Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
Research Institute of Smart Energy, The Hong Kong Polytechnic University, Hong Kong, China
Shenzhen Research Institute, The Hong Kong Polytechnic University, Shenzhen, China
Show Author Information

Abstract

In large-scale buildings, conventional load-based sequencing strategies often control the chiller plants to fully meet cooling demand until the end of office hours to maintain the indoor comfort, leading to significant waste of cooling energy. Stopping cooling supply earlier could significantly reduce the cooling energy use but may fail to maintain necessary thermal comfort. To address this critical issue, this study proposes an innovative and optimal “soft early-stop” strategy that optimizes the trade-off between the early reduction of cooling supply and thermal comfort. To achieve this objective precisely and reliably, the key technical challenge is to predict the cooling energy demand during the office ending hours. This is solved by introducing the novel concept of “minimum cooling energy demand,” which bridges the gap between usable cold energy stored in the building thermal mass and cooling demand during office ending hours. Usable cold storage is predicted via a resistance-capacitance (RC) model, while cooling demand is forecasted using a TPE-LightGBM model, enabling dynamic optimization of early-stop times and reduced chiller capacity. Simulation test results show that, compared to conventional load-based control, the proposed strategy achieves energy savings of 11.3% and 23.3% for indoor air temperature rises of 1 K and 2 K, respectively, by proactively reducing chiller cooling capacity 30–180 minutes before the end of office hours. This strategy provides robust performance with prediction errors below 10%, offering potential for reducing cooling energy consumption without the need for infrastructure upgrades.

References

【1】
【1】
 
 
Building Simulation
Pages 2245-2264

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Lin X, Shan K, Li H, et al. Optimal soft early-stop of multi-chiller plants for effective utilization of passive cold storage in buildings. Building Simulation, 2026, 19(9): 2245-2264. https://doi.org/10.1007/s12273-026-1494-0

5

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 20 April 2026
Revised: 18 June 2026
Accepted: 27 July 2026
Published: 11 September 2026
© Author(s) 2026

This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/