AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Development and validation of a dynamic quasi-2D RC model for decoupled radiant cooling systems

Yizhen Li1, Yujiao Du1, Huijun Wu2, Xinhua Xu3, Gongsheng Huang1( )
Department of Architecture and Civil Engineering, City University of Hong Kong, Hong Kong, China
School of Civil Engineering, Guangzhou University, Guangzhou 510006, China
Department of Building Environment and Energy Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Show Author Information

Abstract

In hot and humid climates, the application of conventional radiant cooling systems is often limited by condensation risk and insufficient cooling capacity. To address these limitations, a decoupled radiant cooling (DRC) technology has been developed, in which a new type of radiant cooling panel is adopted. The new panel, titled as DRC panel, uses an air layer that is sealed by an infrared-transparent membrane to separate its radiant cooling surface from the air-contact surface. This design enables high radiant cooling capacity while minimizing the risk of condensation. However, existing research mainly focuses on the thermal performance analysis of DRC systems using steady-state models. There is a lack of research on their dynamic behavior under varying external boundary conditions and internal load disturbances. This study addresses the research gap in the dynamic thermal performance analysis of DRC systems by developing a quasi-2D dynamic model using a resistance-capacitance (RC) thermal network, calibrated through a non-dominated sorting genetic algorithm Ⅱ (NSGA-Ⅱ). The model was validated against experimental data, achieving mean absolute errors (MAE) and root mean square errors (RMSE) not exceeding 0.28 ℃ and 0.34 ℃ for both the membrane surface temperature and the radiant cooling surface temperature. The model also showed reasonable agreement in predicting the indoor air temperature and outlet water temperature. A simulation platform based on the developed model was constructed for a typical office conditioned by a DRC system, demonstrating its effectiveness as a tool for analyzing the dynamic thermal environment. The results highlight the model’s ability to provide accurate predictions, laying a solid foundation for future studies on energy consumption forecasting and operation control method development for DRC systems.

References

【1】
【1】
 
 
Building Simulation
Pages 1961-1980

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li Y, Du Y, Wu H, et al. Development and validation of a dynamic quasi-2D RC model for decoupled radiant cooling systems. Building Simulation, 2026, 19(8): 1961-1980. https://doi.org/10.1007/s12273-026-1476-2

2

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 16 April 2026
Revised: 22 June 2026
Accepted: 29 June 2026
Published: 01 August 2026
© Author(s) 2026

This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/