AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (5.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Numerical study of indoor pollutant inter-unit dispersion in multi-storey street-canyon buildings due to single-sided wind-driven natural ventilation

Xiaojian Xie1( )Shen Li1Yubo You1Jian Hang2Zhiwen Luo3Xiaole Chen1Jun Xie1
School of Energy Science and Engineering, Nanjing Normal University, Nanjing, Jiangsu, China
School of Atmospheric Sciences, Sun Yat-sen University, Zhuhai, Guangdong, China
Welsh School of Architecture, Cardiff University, UK
Show Author Information

Abstract

In urban buildings, indoor pollutants disperse outward through windows and may reenter other rooms, causing inter-unit dispersion. To address public concern regarding cross-infection risk from infectious individuals in self-isolation during window ventilation, this study quantified inter-unit dispersion of indoor respiratory aerosols in two-dimensional ideal street canyons with aspect ratios (AR = H/W = 0.5–3). Indoor-outdoor coupled airflow under single-sided ventilation conditions was simulated using the RNG k-ε turbulence model. Room air change rate (ACH) was determined via the tracer gas decay method. Dispersion of indoor respiratory aerosols in street canyons and multi-storey buildings was simulated using the tracer gas technique and quantified by reentry ratio (Rk). Infection probability (P) was estimated by the Wells-Riley equation. Numerical results shows that the clockwise main vortex in the street canyon dominates pollutant dispersion. The adjacent room of the source room along the main vortex exhibited the highest Rk values. The maximum observed Rk across all ARs was 5.9%. When quanta generation rate q was as low as 13 quanta/h, P values in only three non-source rooms exceeded 5% with the highest value below 7%. When q reached 161 quanta/h, the maximum P values in non-source rooms approximately ranged from 15% to 58% with increasing AR, which could be controlled to less than 10% if the infected or the susceptible wearing N95 mask. Within the parameter space examined, these findings suggest that excessive concern regarding inter-unit transmission by window ventilation may be unwarranted when proper infection control measures are implemented in the source room.

Electronic Supplementary Material

Download File(s)
bs-19-6-1569_ESM.pdf (1,015.2 KB)

References

【1】
【1】
 
 
Building Simulation
Pages 1569-1589

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Xie X, Li S, You Y, et al. Numerical study of indoor pollutant inter-unit dispersion in multi-storey street-canyon buildings due to single-sided wind-driven natural ventilation. Building Simulation, 2026, 19(6): 1569-1589. https://doi.org/10.1007/s12273-026-1446-8

8

Views

1

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 27 October 2025
Revised: 18 March 2026
Accepted: 30 March 2026
Published: 21 July 2026
© Tsinghua University Press 2026