Research Article

Developing an envelope-based direct capture efficiency (EDCE) for evaluating local exhaust ventilation performance

Mingyao Ma1Yiqun Li1Yukun Xu1Changsheng Cao1Jingjing Pei2Bin Li3Lina Zhang4Yongzhe Meng5Jun Gao1( )
School of Mechanical Engineering, Tongji University, Shanghai 200092, China
Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
Ningbo Fotile Kitchen Ware Co., Ltd., Ningbo 315336, China
Qingdao Haier Air Conditioner Co., Ltd., Qingdao 266001, China
Qingdao Haier Intelligent Cooking Appliances Co., Ltd., Qingdao 266001, China
Show Author Information

Abstract

Effective pollutant control in residential kitchens remains a major challenge due to the localized and transient nature of cooking emissions. Conventional indicators such as capture efficiency and removal efficiency fail to distinguish direct pollutant capture from recirculation, leading to overestimated performance evaluations. To address this limitation, this study proposes a novel evaluation framework, Envelope-Based Direct Capture Efficiency (EDCE), which integrates suction envelope visualization with a Virtual Purification Method. By coupling computational fluid dynamics (CFD) with a streamline-based reconstruction algorithm, the EDCE approach enables both qualitative identification of the effective suction boundary and quantitative isolation of true pollutant entrainment. Case studies examine the effects of outlet-to-wall distance and baffle installation distance under typical exhaust flow rates and pot positions. Results indicate that, unlike conventional metrics that exhibit early saturation, EDCE shows a distinct reduction from approximately 0.86 to 0.62 (about 30%), revealing a higher sensitivity to structural variations and providing physically interpretable insights into pollutant entrainment mechanisms. Outlet-to-wall distance is identified as the dominant factor, while baffles enhance lateral pollutant control when placed at optimal spacing. This methodological innovation establishes a robust, geometry-driven basis for evaluating range hood performance and offers practical guidance for the design and optimization of local ventilation systems.

Electronic Supplementary Material

Download File(s)
bs-19-4-1155_ESM.pdf (438.5 KB)

References

【1】
【1】
 
 
Building Simulation
Pages 1155-1170

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ma M, Li Y, Xu Y, et al. Developing an envelope-based direct capture efficiency (EDCE) for evaluating local exhaust ventilation performance. Building Simulation, 2026, 19(4): 1155-1170. https://doi.org/10.1007/s12273-026-1427-y

8

Views

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 26 November 2025
Revised: 23 January 2026
Accepted: 06 February 2026
Published: 16 May 2026
© Tsinghua University Press 2026