Designing water spray systems to mitigate particulate matter pollution in an urban area

Chichuan Qin1, Xuelin Zhang1,2,3( ), A. U. Weerasuriya4, Kenny C.S. Kwok5, Kelvin T. F. Chan1,2,3, Xiuzhi Chen6, Naiming Yuan1,2
School of Atmospheric Sciences, Sun Yat-sen University, Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Zhuhai, China
Key Laboratory of Tropical Atmosphere-Ocean System (Sun Yat-sen University), Ministry of Education, Zhuhai 519000, China
Guangdong Province Key Laboratory for Climate Change and Natural Disaster Studies, Sun Yat-sen University, Zhuhai, China
Department of Construction and Quality Management, School of Science and Technology, Hong Kong Metropolitan University, Ho Man Tin, Hong Kong, China
Wind, Waves and Water, School of Civil Engineering, The University of Sydney, Australia
Guangdong Province Data Center of Terrestrial and Marine Ecosystems Carbon Cycle, Sun Yat-sen University, Zhuhai 510245, China
Show Author Information

Abstract

Water spray systems can mitigate particulate matter (PM) pollution by spraying water droplets to capture PM in the air. This study evaluates the PM removal using water spray systems in an urban site in Tsuen Wan, Hong Kong, through computational fluid dynamics (CFD) simulations. A droplet capturing model considering the relative motion of droplet and PM was integrated into the CFD simulations to model the mechanism of the droplet in removing PM in a realistic urban area. CFD simulations evaluated three design parameters: installation location, spray pressure, and water flow rate. The results show that installing the water spray system at the road center is the most efficient and quickest way to remove PM in the urban site. However, increasing spray pressure has limited improvements in PM removal efficiency because the background wind speeds deter the droplet movements. Instead, increasing the water flow rate significantly increases the droplet concentration in the air, thereby reducing personal intake of PM by pedestrians up to 16.14%. In addition, this study revealed that CFD simulations that omit the droplets’ capturing effect can result in 7.88%–15.44% underestimation of PM removal by water spray systems. Finally, this study recommends designing water spray systems with high flow rates in road centers and evaluating their performance in removing PM by using CFD simulations with the droplets’ capturing effect to mitigate PM pollution in urban areas.

References

【1】
【1】
 
 
Building Simulation
Pages 383-405

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Qin C, Zhang X, Weerasuriya AU, et al. Designing water spray systems to mitigate particulate matter pollution in an urban area. Building Simulation, 2026, 19(2): 383-405. https://doi.org/10.1007/s12273-026-1395-2

1650

Views

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 10 September 2025
Revised: 19 October 2025
Accepted: 24 November 2025
Published: 13 March 2026
© Tsinghua University Press 2026