AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Climate-adaptive and sustainability-driven passive design prototypes: Healthy natural ventilation strategies for university teaching buildings in high-density urban areas of China

Kailai Zhou1, Jiawei Leng1,2( ), Xin Zhou1, Kai Zhou1, Jining Zhao1
School of Architecture, Southeast University, Nanjing 210096, China
Nanjing Urban Planning Design Institute of Southeast University, Nanjing 210096, China
Show Author Information

Abstract

Maintaining indoor air quality (IAQ) in dense university campuses is increasingly challenging due to urban densification and limited winter ventilation. This study proposes six climate-adaptive, health-oriented passive ventilation prototypes, combining three inlets (M1: underground pipes; M2: sunken square; M3: windcatcher) and two outlets (N1: negative pressure roof; N2: solar chimney). Using ANSYS Fluent 2024R2, CFD simulations were conducted in five representative high-density Chinese cities across major thermal zones, considering low-rise (T1) and high-rise (T2) urban forms. Results show that under winter closed-window conditions, the N1 configuration achieved higher health ventilation performance (HVP), reducing indoor CO2 by 82.6%–86.0%, while N2 enhanced thermal gain and energy efficiency. Climate zone influenced performance more than urban form type, highlighting the need for climate-specific design strategies. Long-term evaluation under the SSP5-8.5 scenario indicated that recommended prototypes maintained higher HVP in warmer regions and greater stability under extreme conditions in colder regions. This study develops a health-oriented prototype combination design methodology that systematically integrates multiple passive strategies, accounts for climatic adaptability and urban morphology, and provides context-specific solutions to improve IAQ and promote respiratory health. The outcomes offer an expandable, replicable, and operational design method for designing health-focused buildings and guiding sustainable urban renewal in high-density environments.

Electronic Supplementary Material

Download File(s)
bs-19-2-359_ESM.pdf (6.5 MB)

References

【1】
【1】
 
 
Building Simulation
Pages 359-381

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhou K, Leng J, Zhou X, et al. Climate-adaptive and sustainability-driven passive design prototypes: Healthy natural ventilation strategies for university teaching buildings in high-density urban areas of China. Building Simulation, 2026, 19(2): 359-381. https://doi.org/10.1007/s12273-025-1388-6

923

Views

3

Crossref

3

Web of Science

3

Scopus

0

CSCD

Received: 13 July 2025
Revised: 29 October 2025
Accepted: 08 November 2025
Published: 04 February 2026
© Tsinghua University Press 2026