AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

A degradation knowledge guided health indicator for chiller performance monitoring based on variational information bottleneck

Qiao Deng1, Yufei Liu1, Yifeng Yuan2, Zhiwen Chen1,3( ), Yalin Wang1, Weihua Gui1
School of Automation, Central South University, Changsha 410083, China
Shenzhen DAS Intellitech Co., Ltd., Shenzhen 518057, China
Xiangjiang Laboratory of Hunan Province, Changsha 410205, China
Show Author Information

Abstract

The performance of chillers significantly impacts the operating efficiency of heating, ventilation, and air conditioning systems. Accurately capturing and monitoring chiller performance changes is essential for ensuring efficient operation and implementing effective maintenance strategies. However, existing performance monitoring methods are sensitive to fluctuations in operating conditions, have difficulty perceiving subtle performance degradation trends, and insufficiently utilize knowledge of equipment degradation mechanisms. To this end, this paper proposes a degradation knowledge-guided health indicator for chiller performance monitoring based on variational information bottleneck (VIB). First, the steady-state operation data are screened and divided into conditional and state variables. Then, the VIB model predicts the state variables, and the residual is calculated to obtain the health status features, which are independent of operating conditions. Subsequently, a degradation trend is constructed using equipment degradation knowledge, which guides the design of a feature extraction structure comprising a shared encoder and an independent decoder to identify common degradation patterns across maintenance cycles. Finally, the extracted degradation features are subjected to dimensionality reduction to derive health indicators, which are combined with cumulative sum analysis to achieve performance monitoring. Validated using nearly five years of operating data from chillers in an actual building, the proposed method achieves monotonicity of approximately 0.80, correlation exceeding 0.92, and robustness exceeding 0.98 over three maintenance cycles, all of which exceed state-of-the-art benchmarks. Furthermore, the method can detect the onset of degradation and issue warnings over 80 hours earlier than traditional engineering practice, demonstrating its superior reliability and practical value for real-world chiller performance monitoring.

References

【1】
【1】
 
 
Building Simulation
Pages 315-332

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Deng Q, Liu Y, Yuan Y, et al. A degradation knowledge guided health indicator for chiller performance monitoring based on variational information bottleneck. Building Simulation, 2026, 19(2): 315-332. https://doi.org/10.1007/s12273-025-1383-9

606

Views

2

Crossref

2

Web of Science

2

Scopus

0

CSCD

Received: 25 June 2025
Revised: 14 October 2025
Accepted: 03 November 2025
Published: 18 February 2026
© Tsinghua University Press 2026