AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

An unsupervised method of HVAC energy disaggregation and demand response potential estimation

Ying Zhang1,2,§, Ji Li3,§, Wenjie Gang1,2( ), Shukun Dong1, Xiuxia Hao1, Zhengkai Tu4
School of Environmental Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Institute of Building Environment and Energy, China Academy of Building Research, Beijing 100013, China
School of Energy and Power Engineering, Huazhong University of Science and Technology, Wuhan 430074, China

§ Ying Zhang and Ji Li contributed equally to this work.

Show Author Information

Abstract

The heating, ventilation, and air conditioning (HVAC) system is a promising flexibility resource for building energy management and grid stability. Quantitatively assessing HVAC demand response (DR) potential is crucial for integrating buildings into DR programs. However, utilities and load aggregators typically only have total building energy data, making HVAC energy disaggregation challenging. This study proposes an unsupervised and hybrid time-frequency domain decomposition method (MSTL-VMD) to disaggregate HVAC energy from total consumption and an improved equivalent thermal parameter model to quantify DR potential while considering outdoor weather, indoor environment, and occupant comfort. The effectiveness of the proposed method is verified based on historical data from 10 office buildings over 3 years. The results indicate that the HVAC energy can be accurately disaggregated using the MSTL-VMD method with NRMSE of 2.4%–12.6%. The proposed equivalent thermal parameter model can realize HVAC energy regression with an R2 value exceeding 0.8 for 80% of cases. A 1 ℃ indoor temperature increase results in energy savings of 7.3%–18.4% over the summer. The proposed method provides utilities and load aggregators with an effective and practical technique to quantify HVAC DR potential, enabling the development of optimal energy management strategies to enhance energy system resilience and efficiency.

Electronic Supplementary Material

Download File(s)
bs-18-12-3317_ESM.pdf (114.1 KB)

References

【1】
【1】
 
 
Building Simulation
Pages 3317-3335

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhang Y, Li J, Gang W, et al. An unsupervised method of HVAC energy disaggregation and demand response potential estimation. Building Simulation, 2025, 18(12): 3317-3335. https://doi.org/10.1007/s12273-025-1367-y

936

Views

0

Crossref

1

Web of Science

1

Scopus

0

CSCD

Received: 24 July 2025
Revised: 10 September 2025
Accepted: 26 September 2025
Published: 26 December 2025
© Tsinghua University Press 2025