AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Comparative analysis of cascade and single heat pumps for cooling and hot water supply performance: Experiments and building simulation

Beom-Jun Kim1Seheon Kim2Mingeon Go3Hong-Jin Joo4Kyoung Ho Lee4Jae-Weon Jeong2( )
Department of Building Energy Research, Korea Institute of Civil Engineering and Building Technology, 283, Goyang-daero, Ilsanseo-gu, Goyang, 10223, Republic of Korea
Department of Architectural Engineering, College of Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul, 04763, Republic of Korea
SAMHWAACE, 194, Hogupo-ro, Namdong-gu, Incheon, 21655, Republic of Korea
Korea Institute of Energy Research, 152, Gajeong-ro, Yuseong-gu, Daejeon, 34129, Republic of Korea
Show Author Information

Abstract

This study presents a comparative analysis of cascade and single heat pump systems for simultaneous cooling and domestic hot water supply, aimed at supporting building electrification and carbon neutrality goals. The novelty of this work lies in its integrated experimental and simulation-based evaluation of cascade heat pump performance, addressing a gap in existing studies that typically analyze either mode separately. A field test was conducted in a real building environment using two configurations: a cascade heat pump system managing both cooling and hot water functions, and two separate single heat pumps. Performance metrics such as cooling energy efficiency ratio and hot water coefficient of performance were measured and compared under identical boundary conditions. In addition, a transient simulation study was carried out using transient simulation tool for representative summer days in office and residential buildings, assessing primary energy consumption and carbon emissions based on experimental data. The cascade system achieved up to 15.3% improvement in energy efficiency ratio, 23.7% reduction in primary energy use for office buildings, and up to 24% reduction in CO2 emissions. These findings demonstrate the practical applicability of cascade heat pumps in energy-saving retrofit projects, especially for space-constrained buildings, and provide empirical and simulation-based evidence supporting their integration into sustainable building strategies.

Electronic Supplementary Material

Download File(s)
bs-19-1-71_ESM.pdf (136.5 KB)

References

【1】
【1】
 
 
Building Simulation
Pages 71-93

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Kim B-J, Kim S, Go M, et al. Comparative analysis of cascade and single heat pumps for cooling and hot water supply performance: Experiments and building simulation. Building Simulation, 2026, 19(1): 71-93. https://doi.org/10.1007/s12273-025-1362-3

420

Views

0

Crossref

1

Web of Science

0

Scopus

0

CSCD

Received: 17 March 2025
Revised: 22 August 2025
Accepted: 04 September 2025
Published: 05 January 2025
© Tsinghua University Press 2026