AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Adaptive reuse strategies in urban centers: Experimental validation using neural networks and real building data

Razmig Garboushian1, Yannik Sigouin1, Adham M. Elmalky2( ), Mohamad T. Araji1,2
School of Architecture, University of Waterloo, 7 Melville St S, Cambridge, ON N1S 2H4, Canada
Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada
Show Author Information

Abstract

Adaptive reuse in urban centers aims to achieve net-zero energy goals by lowering energy consumption and improving thermal comfort in existing buildings. The combined effects of building expansions on energy performance, and daylighting availability remain unexplored. This paper developed a novel simulation model by applying multi-building data and neural-networks framework to examine the impact of adaptive reuse through variables including number of floors, energy generation, façade glazing, and building expansions in various directions. The developed model was validated by comparing simulated and actual energy use of several buildings, yielding an average error of 7.88%. This error represents the deviation between the simulated and actual energy use intensity values. Energy demand reduced by expansion along the East–West axis was 41% greater than that from expansion in the South direction. This was confirmed by sensitivity analysis, with R values of approximately 0.68 for East and West expansions, and 0.16 for the South. Overall, this study demonstrates that expanding buildings in the East–West direction tends to be the most energy-efficient approach for increasing occupied spaces, with its effectiveness potentially influenced by factors such as site location, building orientation, and climatic conditions.

References

【1】
【1】
 
 
Building Simulation
Pages 2417-2433

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Garboushian R, Sigouin Y, Elmalky AM, et al. Adaptive reuse strategies in urban centers: Experimental validation using neural networks and real building data. Building Simulation, 2025, 18(9): 2417-2433. https://doi.org/10.1007/s12273-025-1310-2

990

Views

1

Crossref

1

Web of Science

1

Scopus

0

CSCD

Received: 16 January 2025
Revised: 21 April 2025
Accepted: 22 May 2025
Published: 14 August 2025
© Tsinghua University Press 2025