Research Article

Interstitial condensation analysis and moisture control for office building walls in China

Hanyu Yang1, Lixin Sun1, Xianqi Huang2,3,4, Ana Sofia Guimarães5, Chi Feng2,3,4( )
State Key Laboratory of Building Safety and Built Environment, China Academy of Building Research, Beijing 100013, China
School of Architecture and Urban Planning, Chongqing University, Chongqing 400045, China
Key Laboratory of New Technology for Construction of Cities in Mountain Area, Ministry of Education, Chongqing University, Chongqing 400045, China
Sichuan-Chongqing Joint Lab of Advanced Eco-Materials with Safety and Energy Efficiency for Civil Engineering, Chongqing University, Chongqing 400045, China
CONSTRUCT-LFC, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
Show Author Information

Abstract

Accurate analysis of interstitial condensation for walls could influence the energy efficiency and durability of buildings. The Chinese standard adopts the classic 1-D steady-state vapor diffusion model to assess the risk of interstitial condensation in the heating period in severe cold and cold regions, where the indoor and outdoor boundary conditions could be approximated as a steady state. However, its applicability is subject to doubt in other scenarios where indoor and outdoor boundary conditions are highly dynamic. The transient hygrothermal model subsequently provides more accurate results but is also more complicated. This paper aims to investigate the advisable interstitial condensation calculation method for office buildings in various climate zones in China. The hygrothermal properties of four typical building materials were tested first. Next, the steady-state and transient calculation methods were compared. Finally the optimized vapor diffusion resistance factors of vapor barriers were proposed. Results show that the constant and variable material properties have a negligible effect on interstitial condensation analysis, with a maximum difference of 2.5% in relative humidity (RH). However, the steady-state and transient calculations have discrepant results, with the maximum difference in RH exceeding 10%. Wind-driven rain also plays an important role, with the maximum difference in RH exceeding 15%. Besides, the EPS internal thermal insulation composite system (ITICS) and rock wool external thermal insulation composite system (ETICS) require an additional vapor barrier in Shanghai and Guangzhou. Since the reduction of building’s sensible and latent heat consumption caused by the vapor barrier is limited, the vapor permeability resistance of the vapor barrier only needs to consider moisture control.

References

【1】
【1】
 
 
Building Simulation
Pages 1929-1944

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yang H, Sun L, Huang X, et al. Interstitial condensation analysis and moisture control for office building walls in China. Building Simulation, 2025, 18(8): 1929-1944. https://doi.org/10.1007/s12273-025-1307-x

1090

Views

5

Crossref

5

Web of Science

5

Scopus

0

CSCD

Received: 03 March 2025
Revised: 17 May 2025
Accepted: 21 May 2025
Published: 28 July 2025
© Tsinghua University Press 2025