AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Data-driven modeling and sensitivity analysis of pressure differential deviations in pharmaceutical cleanrooms under static conditions and dynamic disturbances

Yufan Chang1,2, Jie Zong1,2, Yan Hu1,2, Zhengtao Ai1,2( ), Weichao Zhang3, Wenxuan Zhao4, Zhongbing Liu5, Rongpeng Zhang4
Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China
National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha, Hunan, China
China Electronics System Engineering No. 2 Construction Co., Ltd., Wuxi, Jiangsu, China
School of Architecture and Planning, Hunan University, Changsha, Hunan, China
Key Laboratory of Building Safety and Energy Efficiency of the Ministry of Education, Hunan University, Changsha, Hunan, China
Show Author Information

Abstract

Pressure differential deviations under static conditions and pressure convergence fluctuations under dynamic disturbances are widely reported problems with pressure differential control in pharmaceutical cleanrooms, yet their underlying mechanisms and key reasons remain insufficiently explored. This study performed a field survey and model-based simulations to identify the major influencing parameters and quantify their influence on pressure differentials. Twelve pharmaceutical cleanrooms with varying environmental control parameters were included in the field survey, all of which were served by a variable air volume (VAV) ventilation system. Large deviations between actual and design pressure differentials were found, ranging from 10% to 42.5%, and a total of 24 uncertain parameters and their respective uncertainty ranges were identified. Based on the field survey, a data-driven pressure differential response model was developed using MATLAB/Simulink platform. The model fully took into account the system dynamics and facilitated real-time monitoring and control of the pressure differential. Sobol-based sensitivity analysis was then conducted to identify key influencing parameters of pressure differential deviations. The simulated results revealed that static pressure differential deviations were predominantly influenced by pressure sensing accuracy, exhaust airflow accuracy, and duct impedance, while dynamic disturbances were mainly driven by room envelope airtightness and supply airflow accuracy. The interactions between connected zones were pronounced. Rooms with higher branch duct impedance experienced smaller pressure differential deviations due to natural buffering characteristics, while the parameter uncertainties in these rooms significantly affected pressure differential in other rooms. These findings offer practical guidance for the design and operation of precise pressure differential control in pharmaceutical cleanrooms.

References

【1】
【1】
 
 
Building Simulation
Pages 2019-2038

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Chang Y, Zong J, Hu Y, et al. Data-driven modeling and sensitivity analysis of pressure differential deviations in pharmaceutical cleanrooms under static conditions and dynamic disturbances. Building Simulation, 2025, 18(8): 2019-2038. https://doi.org/10.1007/s12273-025-1305-z

1181

Views

5

Crossref

5

Web of Science

5

Scopus

0

CSCD

Received: 02 March 2025
Revised: 29 April 2025
Accepted: 16 May 2025
Published: 27 June 2025
© Tsinghua University Press 2025