Optimizing building envelope design across various French climates: A multi-objective approach using NSGA Ⅱ and RMP method

Kamal Alaili1( ), Ahmed Kamel Tedjditi2, El Mostapha Moutaouakil1, Abdelkader Outzourhit3,4
CESI LINEACT UR7527, 19 Avenue de la Forêt de Haye, Vandoeuvre-lès-Nancy, 54500, France
CESI LINEACT UR7527, 2 Allée des Foulons, Lingolsheim, 67381, France
Laboratory (LaMEE), Faculty of Sciences Semlalia, Cadi Ayyad University, Marrakesh, Morocco
MSN department, Mohamed Ⅵ Polytechnic University, Benguerir, Morocco
Show Author Information

Abstract

Architects face a major challenge in designing buildings that enhance human comfort while minimizing energy consumption. To address this, the present work presents a novel multi-objective optimization approach, aiming to determine the optimal building envelope design. The developed approach focuses on minimizing energy consumption for both heating and cooling demand. Therefore, the methodology follows three basic steps, namely, (ⅰ) energy simulation using EnergyPlus software, (ⅱ) optimization (non-dominant sorting genetic algorithm NSGA Ⅱ), and (ⅲ) multi-criteria decision analysis (MCDA). In this study, simulations were firstly carried out on a single-story family house located in three distinct French climates: Nancy (semi-continental climate), Embrun (oceanic climate), and Nice (Mediterranean climate) in order to analyze the effect of climate on optimization results. For each site, seven decision variables for optimization problem are considered, including, wall insulation material properties, building rotation, glazing type, window-to-wall ratio (WWR), heating and cooling set-point temperatures, and infiltration rate. Pareto fronts are used to display the optimization results, which are obtained through NSGA Ⅱ iterations depending on the specified optimization objectives of heating and cooling demand. The optimization (after 900 iterations) yielded 10 Pareto solutions for Nancy, 26 for Embrun, and 23 for Nice. The top-ranked Pareto-optimal solution, considering the requirements of the French building code (RT2012/RE2020), Passivhaus standard, and client preferences, which minimizes cooling, heating, and total energy consumption, was selected using a new MCDA method called ranking with multiple reference profiles (RMP). The results showed that when equal weight is given to the heating and cooling objective functions, total energy consumption decreases by 8.71% for Nancy, by 9.81% to 18.34% for Embrun, and by 6.52% to 21.7% for Nice, compared to the initial design, depending on the adopted lexicographic order.

References

【1】
【1】
 
 
Building Simulation
Pages 1677-1696

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Alaili K, Tedjditi AK, Moutaouakil EM, et al. Optimizing building envelope design across various French climates: A multi-objective approach using NSGA Ⅱ and RMP method. Building Simulation, 2025, 18(7): 1677-1696. https://doi.org/10.1007/s12273-025-1280-4

1071

Views

15

Crossref

13

Web of Science

12

Scopus

0

CSCD

Received: 01 February 2025
Revised: 13 March 2025
Accepted: 27 March 2025
Published: 27 June 2025
© Tsinghua University Press 2025