AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

A novel convective-radiant personalized environmental control system for intermittent heating demand

Yifan Wu1,4, Shiying Li1,4, Yihui Li1,4, Hongli Sun2,4, Borong Lin1,4( ), Xiaohua Liu1, Mengfan Duan3,4, Ziqian Zhou1,4
Department of Building Science, Tsinghua University, Beijing 100084, China
College of Architecture and Environment, Sichuan University, Chengdu 610065, China
School of Energy and Environment, Southeast University, Nanjing 211189, China
Key Laboratory of Eco Planning & Green Building, Ministry of Education, Tsinghua University, Beijing 100084, China
Show Author Information

Abstract

Building energy consumption is mainly influenced by thermal load, equipment efficiency, service space, and operating time. While extensive research has focused on reducing load and improving efficiency, significant energy-saving potential remains in optimizing time and space of usage. This study proposes a novel convective-radiant desktop-based terminal that integrates personalized environmental control system with convective-radiant terminals, enabling “part-time, localized-space” operations to enhance energy savings. It includes a discussion on the structural design of the device and experimental analysis of its local environmental control and intermittent operation. The design incorporates a convective heat exchanger and radiant panel embedded in a height-adjustable desktop. Experimental results showed that the combination of the radiant panel and air outlet beneath the desktop accumulates heat in this area during heating, creating a “cool head, warm feet” thermal comfort effect. The maximum vertical temperature difference was 0.7 ℃ in radiation mode. For intermittent operation, the temperature response matching coefficient (TRMC) of the proposed terminal was 3.4 times that of floor heating and 2.1 times that of fan coil units, indicating superior performance. Besides, this novel terminal provides effective thermal comfort in both sitting and standing positions, offering potential energy savings in open-plan offices. By extending the room temperature setpoint to 16–18 ℃ in winter, the terminal can reduce energy consumption by 3.64%–12.52%. These findings provide a reference for personalized environmental control systems and intermittent heating strategies.

References

【1】
【1】
 
 
Building Simulation
Pages 1355-1376

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wu Y, Li S, Li Y, et al. A novel convective-radiant personalized environmental control system for intermittent heating demand. Building Simulation, 2025, 18(6): 1355-1376. https://doi.org/10.1007/s12273-025-1270-6

1268

Views

11

Crossref

10

Web of Science

10

Scopus

0

CSCD

Received: 14 January 2025
Revised: 22 February 2025
Accepted: 13 March 2025
Published: 28 April 2025
© Tsinghua University Press 2025