AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

An unsupervised non-intrusive load monitoring method for HVAC systems of office buildings based on MSTL

Lihong Su1, Wenjie Gang1,2,3( ), Ying Zhang1,2, Shukun Dong2, Zhengkai Tu4
Institute of Artificial Intelligence, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China
School of Environmental Science and Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China
Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science and Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China
School of Energy and Power Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074 China
Show Author Information

Abstract

Heating, ventilation, and air conditioning (HVAC) systems constitute a significant portion of the office building load and are important flexibility resources. However, the HVAC loads are often inaccessible to the utility or load aggregators who only have total load data. Most existing studies require subloads for supervised disaggregation or prior knowledge for unsupervised disaggregation, but such information is hard to obtain. It is necessary to develop an effective, completely unsupervised non-intrusive monitoring method to obtain the HVAC load data. In this study, a multiple seasonal-trend decomposition using the LOESS (MSTL) method is proposed to disaggregate the HVAC load from the total metered electricity data of office buildings. The effects of periodic types (daily, weekly, monthly, etc.), periodic sequences, and parallel/serial structures are analyzed. The proposed method is verified based on the historical electricity data of ten buildings. The results show that the proposed MSTL can accurately disaggregate the HVAC load with a coefficient of variation of the root mean square error (CVRMSE) of 10.94%, a normalized root mean squared error (NRMSE) of 2.1%, and a weighted absolute percentage error (WAPE) of 8.52%. Compared to single-cycle STL, the proposed method can significantly improve load disaggregation performance, with a maximum reduction of 16.36% in CVRMSE, 5.3% in NRMSE, and 12.91% in WAPE. Backward-chain-based MSTL is recommended with higher accuracy and robustness. The proposed method provides an effective solution for utilities or load aggregators to improve demand response management and grid stability.

References

【1】
【1】
 
 
Building Simulation
Pages 1641-1657

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Su L, Gang W, Zhang Y, et al. An unsupervised non-intrusive load monitoring method for HVAC systems of office buildings based on MSTL. Building Simulation, 2025, 18(7): 1641-1657. https://doi.org/10.1007/s12273-025-1268-0

978

Views

2

Crossref

2

Web of Science

2

Scopus

0

CSCD

Received: 28 December 2024
Revised: 20 February 2025
Accepted: 10 March 2025
Published: 11 April 2025
© Tsinghua University Press 2025