AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Influence of airflow and the location of infected individuals on occupant exposure in classrooms without mechanical ventilation during the winter

Zhixi Qing1Weirong Zhang1( )Weijia Zhang1Haotian Zhang1Yingli Xuan2
Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Department of Architecture, Tokyo Polytechnic University, Tokyo, Japan
Show Author Information

Abstract

Winter poses a high risk for spreading infectious respiratory diseases, particularly in classrooms, which are known hotspots for cross-infection. The health hazards in classrooms lacking mechanical ventilation systems often go unnoticed. To address this issue, we studied the risk of respiratory infection transmission in such environments during winter by assessing the spread of contaminants using computational fluid dynamics (CFD). We evaluated four common airflow setups (split-type air conditioner, open door, open window, and both door and window open) in classrooms without mechanical ventilation. Our findings indicate that while split air conditioners provide optimal thermal comfort, they significantly increase exposure risk. Conversely, simply opening a door can effectively balance thermal comfort with a reduced exposure risk—particularly when the infected individual is near the door, leading to a minimal 0.01% average intake fraction. Furthermore, under varying ventilation scenarios, the sensitivity of exposure risk to location changes of infected individuals differs significantly. Specifically, when a split-type air conditioner is used, occupant exposure is largely unaffected by changes in the location of the infected individual. However, the exposure risk becomes highly sensitive to location changes of infected individuals when a door or window is used for ventilation. Strategic positioning of the infected individual can decrease indoor exposure risk by up to 94% with the door open and 67% with the window open. Additionally, when the door and window are both open, the dependency of occupant exposure on the location of the infected individual decreases. In this case, the exposure risk for indoor occupants is low, regardless of the position of the infected individual.

References

【1】
【1】
 
 
Building Simulation
Pages 829-846

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Qing Z, Zhang W, Zhang W, et al. Influence of airflow and the location of infected individuals on occupant exposure in classrooms without mechanical ventilation during the winter. Building Simulation, 2025, 18(4): 829-846. https://doi.org/10.1007/s12273-025-1239-5

596

Views

2

Crossref

2

Web of Science

2

Scopus

0

CSCD

Received: 09 October 2024
Revised: 13 December 2024
Accepted: 03 January 2025
Published: 21 February 2025
© Tsinghua University Press 2025