AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

An adjacent-effects resistant damper integrating control and measurement functions for duct systems

Ruoyin Jing1, Ran Gao1( ), Song Nie1, Xinpeng Hao2, Changqing Yang1, Angui Li1
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055, China
China Railway Siyuan Survey and Design Institute Group Co., Ltd., Wuhan, China
Show Author Information

Abstract

To ensure a comfortable building environment necessitates accurate measurement and control of air volume within duct systems to meet predetermined requirements for each area. Traditional eccentric torque dampers’ measurement accuracy may be compromised by adjacent effects from local components, resulting in significant measurement errors. To solve this problem, the study combines CFD numerical simulation and full-scale experimental validation to derive a formula for controlling air volume within the dampers under operational condition. Based on the formula, a novel torque damper is developed, capable of effectively controlling and accurately measuring air volume in duct systems. By linking the two blades, the damper resists the adjacent effects of local components (elbow, variable diameter, tee) on air volume measurements without the need for additional devices, ensuring a measurement error within ±5.5%. Additionally, the novel dampers have lower resistance compared to traditional dampers. This paper provides a reference for accurately measuring and effectively controlling air volume, while also maximizing the potential benefits of multi-leaf dampers.

References

【1】
【1】
 
 
Building Simulation
Pages 2199-2212

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Jing R, Gao R, Nie S, et al. An adjacent-effects resistant damper integrating control and measurement functions for duct systems. Building Simulation, 2024, 17(12): 2199-2212. https://doi.org/10.1007/s12273-024-1189-3

844

Views

10

Crossref

10

Web of Science

10

Scopus

0

CSCD

Received: 08 July 2024
Revised: 29 August 2024
Accepted: 10 September 2024
Published: 29 October 2024
© Tsinghua University Press 2024