Performance evaluation of high-volume evacuation for removing droplets during dental treatment

Chaojie Xing1,2, Zhengtao Ai1,2( ), Cheuk Ming Mak3, Hai Ming Wong4
Department of Civil Engineering, Hunan University, Changsha 410082, China
National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha, Hunan, China
Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, China
Faculty of Dentistry, The University of Hong Kong, Pok Fu Lam, Hong Kong Island, Hong Kong, China
Show Author Information

Abstract

The high-volume evacuation (HVE) is commonly employed as a primary source control measure for removing splatter emitted from mouth during dental treatments, but there is still a lack of comprehensive understanding of its efficiency. Based on our previous experiments on the emission characteristics during dental treatments, this study employed computational fluid dynamics (CFD) simulations to investigate the impact of emission parameters (droplet size, emission velocity, emission angle), HVE usage methods (distance between HVE and the droplet release source), and HVE suction flow rates on its removal efficiency. The effect of HVE on fallow time (FT) was also examined. Cumulative removal efficiency that accurately reflected the HVE effect was proposed as an evaluation index. It was found that emission velocity and distance between HVE and the source were key factors determining cumulative removal efficiency. When the distance was 4 cm, the cumulative removal efficiencies for low-velocity (0.8 m/s), medium-velocity (3.4 m/s), and high-velocity droplets (6.0 m/s) were approximately 97.9%, 73.6%, and 58.0%, respectively. For high-velocity droplets at 6.0 m/s, decreasing the distance from 4 cm to 2 cm and 1 cm increased the cumulative removal efficiency from 58.0% to 76.7% and 100%. This study was expected to enhance the understanding of HVE performance and provide information on its usage method. It also indicated the need for developing advanced control measures that could have high efficiency in removing both low-velocity and high-velocity droplets.

References

【1】
【1】
 
 
Building Simulation
Pages 2263-2280

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Xing C, Ai Z, Mak CM, et al. Performance evaluation of high-volume evacuation for removing droplets during dental treatment. Building Simulation, 2024, 17(12): 2263-2280. https://doi.org/10.1007/s12273-024-1187-5

964

Views

7

Crossref

7

Web of Science

7

Scopus

0

CSCD

Received: 03 March 2024
Revised: 28 August 2024
Accepted: 30 August 2024
Published: 04 November 2024
© Tsinghua University Press 2024