Optimising multi-vent module-based adaptive ventilation using a novel parameter for improved indoor air quality and health protection

Haotian Zhang1Xiaoxiao Ding1Weirong Zhang1( )Weijia Zhang1Yingli Xuan2
Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Department of Architecture, Tokyo Polytechnic University, Tokyo, Japan
Show Author Information

Abstract

As infectious respiratory diseases are highly transmissible through the air, researchers have improved traditional total volume air distribution systems to reduce infection risk. Multi-vent module-based adaptive ventilation (MAV) is a novel ventilation type that facilitates the switching of inlets and outlets to suit different indoor scenarios without changing ductwork layout. However, little research has evaluated MAV module sizing and air velocity selection, both related to MAV system efficiency in removing contaminants and the corresponding level of protection for occupants in the ventilated room. Therefore, the module-source offset ratio (MSOR) is proposed, based on the MAV module size and its distance from an infected occupant, to inform selection of optimal MAV module parameters. Computational fluid dynamics simulations illustrated contaminant distribution in a two-person MAV equipped office. Discrete phase particles modelled respiratory contaminants from the infected occupant, and contaminant concentration distributions were compared under four MAV air distribution layouts, three air velocities, and three module sizes considered using the MSOR. Results indicate that lower air velocities favour rising contaminant levels, provided the ventilation rate is met. Optimal contaminant discharge can be achieved when the line of outlets is located directly above the infected occupant. Using this parameter to guide MAV system design, 85.7% of contaminants may be rendered harmless to the human body within 120 s using the default air vent layout. A more appropriate supply air velocity and air vent layout increases this value to 91.4%. These results are expected to inform the deployment of MAV systems to reduce airborne infection risk.

References

【1】
【1】
 
 
Building Simulation
Pages 113-130

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhang H, Ding X, Zhang W, et al. Optimising multi-vent module-based adaptive ventilation using a novel parameter for improved indoor air quality and health protection. Building Simulation, 2024, 17(1): 113-130. https://doi.org/10.1007/s12273-023-1063-8

755

Views

9

Crossref

10

Web of Science

10

Scopus

0

CSCD

Received: 15 May 2023
Revised: 24 June 2023
Accepted: 06 July 2023
Published: 12 October 2023
© Tsinghua University Press 2023