AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Design and performance of a novel miniaturized electrostatic sampler for efficient airborne particulate matter sampling

Xihui Liu2Yan Wang2Yilun Gao2Cong Liu3( )Jinhan Mo1,2,4,5( )
College of Civil and Transportation Engineering, Shenzhen University, Shenzhen 518060, China
Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Department of Building Science, Tsinghua University, Beijing 100084, China
School of Energy and Environment, Southeast University, Nanjing 210096, China
Key Laboratory of Coastal Urban Resilient Infrastructures (Shenzhen University), Ministry of Education, Shenzhen 518060, China
Key Laboratory of Eco Planning & Green Building (Tsinghua University), Ministry of Education, Beijing 100084, China
Show Author Information

Abstract

Considering that people spend more than 80% of their time indoors, ambient particulate matter (PM) in the built environment could pose severe environmental health risks to public health. PM sampling, a technique for the enrichment of PM in the air, is essential for ambient PM composition analysis to understand its environmental and health effect. The filtering method that is widely used features a complex post-processing and carries the risk of pore clogging. It is a great challenge to sample airborne PM efficiently for subsequent analysis. Here, we proposed a novel miniaturized electrostatic sampler based on corona discharge and a modified vertically focused electric field for efficient PM sampling. Four intercoupling physical fields in the developed sampler were analyzed, including corona discharge, airflow, particle charging and particle deposition. The collection efficiencies for particles with various sizes (0.01–10 μm) were conducted by simulation and the lowest efficiency occurs at about 0.3–0.5 μm. With an increase in discharging voltage from −6 kV to −9 kV, the lowest efficiency rises from 88.2% to 96.6%. An electrostatic sampler entity was manufactured to test the collection efficiency of PM and the results are in good agreement with the simulation. The induced ring plate can significantly improve the total collection efficiency from 35% to 90% under −6 kV discharging voltage in the experiment. The novel electrostatic sampler exhibits potential and enlightenment for efficient and convenient PM sampling.

Electronic Supplementary Material

Download File(s)
bs-16-8-1439_ESM.pdf (2.2 MB)

References

【1】
【1】
 
 
Building Simulation
Pages 1439-1450

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu X, Wang Y, Gao Y, et al. Design and performance of a novel miniaturized electrostatic sampler for efficient airborne particulate matter sampling. Building Simulation, 2023, 16(8): 1439-1450. https://doi.org/10.1007/s12273-023-1059-4

1008

Views

14

Crossref

13

Web of Science

14

Scopus

0

CSCD

Received: 15 March 2023
Revised: 25 June 2023
Accepted: 26 June 2023
Published: 18 July 2023
© Tsinghua University Press 2023