A newly designed BIPV system with enhanced passive cooling and ventilation

Hadi Ahmadi Moghaddam( )Svetlana TkachenkoGuan Heng YeohVictoria Timchenko
School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia
Show Author Information

Abstract

Nowadays, the application of renewable energies such as solar energy in the building sector has increased notably considering the adverse impacts of climate change on human life; hence many studies have focused on the application of photovoltaic panels in buildings. In the current study, a 3D computational fluid dynamics (CFD) model has been developed to evaluate the performance of a newly designed building-integrated photovoltaic (BIPV) system. Given the negative influence of overheating on the lifespan and performance of PV panels, their passive air cooling has been studied. Further, the potential of rooftop-mounted solar panels in passive ventilation of buildings by generating natural convective currents has been explored. The developed CFD model takes into consideration the effects of radiation, conduction, and buoyancy-driven natural convective currents generated by solar PV panels which are heated due to the exposure to solar radiation heat flux. The results suggest that applying a high surface emissivity for the part of the roof beneath the PV panels intensifies the natural convective currents which in turn provides better cooling for PV panels with higher cooling effects at higher solar heat fluxes. Up to a 34% increase in the convective mass flow rate and a 3 K decrease in the mean temperature of the panels were attained by modifying the emissivity of roof surface. Such a 3 K decrease in the operating temperature of the PV panels can enhance their efficiency and lifespan by about 1.56% and 21%, respectively. Based on the operating conditions and system characteristics, the BIPV system yielded an air change rate (ACH) in the range of 3–13 which was considered to be highly prevalent in providing the required passive ventilation for a wide range of applications. It was also observed that the flow dynamics inside the building were affected by both the amount of solar heat load incident on the solar panels and the emissivity of the roof surface behind the panels.

References

【1】
【1】
 
 
Building Simulation
Pages 2093-2107

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ahmadi Moghaddam H, Tkachenko S, Yeoh GH, et al. A newly designed BIPV system with enhanced passive cooling and ventilation. Building Simulation, 2023, 16(11): 2093-2107. https://doi.org/10.1007/s12273-023-1051-z

1215

Views

101

Downloads

23

Crossref

24

Web of Science

26

Scopus

0

CSCD

Received: 12 April 2023
Revised: 10 May 2023
Accepted: 27 May 2023
Published: 01 August 2023
© The Author(s) 2023

This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/