Research Article

Simulation study of the purification system for indoor oil mist control in machining factories

Yukun Wang1Yu Guo1Wenjia Hao1Wei Liu2Zhengwei Long1( )
Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Weijin Road 92, Tianjin 300072, China
Division of Sustainable Buildings, Department of Civil and Architectural, Engineering, KTH Royal Institute of Technology, Brinellvägen 23, Stockholm, 10044, Sweden
Show Author Information

Abstract

High-concentration oil mists can cause serious health problems to workers, which are generally mitigated by ventilation and purification systems. However, the coupling relationship between these systems is not clear. In this study, the effects of purifier outlet direction, purification air volume, installation height, and purification efficiency on indoor oil mist distribution were investigated by numerical simulation using an actual machining factory. The mitigation of oil mist in various combinations of ventilation and purification systems was also discussed. The results show that the outlet direction of the purifier has a great influence on the distribution of oil mist in the factory, and the maximum difference of oil mist concentration in the breathing zone under different orientations is 17%. The best purifier outlet direction is vertically upward. When the purifier outlet direction is upward, a larger purification air volume is beneficial for contaminant removal, and a lower purifier exhaust installation height is helpful for oil mist discharge from the bottom of the factory and reducing the concentration of oil mist in the breathing area. The oil mist concentration of purifier exhaust increases from 0 to 2 mg/m3 and the oil mist concentration in the breathing zone increases by 67%. The combined system of purification system with the roof exhaust system and displacement ventilation system has the optimal pollution removal efficiency and the lowest concentration of oil mist in the breathing zone compared to other systems. The research results can provide a reference for the design, installation, and operation of ventilation and purification systems in machining factories.

References

【1】
【1】
 
 
Building Simulation
Pages 1361-1374

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang Y, Guo Y, Hao W, et al. Simulation study of the purification system for indoor oil mist control in machining factories. Building Simulation, 2023, 16(8): 1361-1374. https://doi.org/10.1007/s12273-023-1020-6

1021

Views

8

Crossref

8

Web of Science

8

Scopus

0

CSCD

Received: 31 January 2023
Revised: 03 March 2023
Accepted: 21 March 2023
Published: 12 July 2023
© Tsinghua University Press 2023