Research Article

Impact of indoor ventilation efficiency on acetone inhalation exposure concentration and tissue dose in respiratory tract

Cong Li1( )Sung-Jun Yoo2Kazuhide Ito2
College of Ocean and Civil Engineering, Dalian Ocean University, Dalian 116023, China
Faculty of Engineering Sciences, Kyushu University, Fukuoka, 816-8580, Japan
Show Author Information

Abstract

A significant feature of the indoor environment is the heterogeneity of airflow and pollutant distributions, which are primarily dependent on ventilation systems. In the case of short- and high-concentration exposures to hazardous chemical pollutants, it may be necessary to precisely determine the concentration in the breathing zone or, more directly, the inhalation exposure concentration in the respiratory tract, rather than the representative room average concentration in an indoor environment, because of the non-uniformity of pollutant concentration distributions. In this study, we developed a computer-simulated person with a detailed respiratory system to predict inhalation exposure concentration and inhalation dose via transient breathing and reported a demonstrative numerical simulation for analyzing acetone concentration distributions in a simplified model room. Our numerical analysis revealed that the ventilation efficiency distribution in a room could change significantly by changing the design of the ventilation system, and that the inhalation exposure concentration estimated by a computer-simulated person could differ from the representative concentration, such as perfect-mixing or volume-averaged acetone concentration, by a factor of two or more.

References

【1】
【1】
 
 
Building Simulation
Pages 427-441

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li C, Yoo S-J, Ito K. Impact of indoor ventilation efficiency on acetone inhalation exposure concentration and tissue dose in respiratory tract. Building Simulation, 2023, 16(3): 427-441. https://doi.org/10.1007/s12273-022-0954-4

878

Views

15

Crossref

12

Web of Science

15

Scopus

0

CSCD

Received: 05 July 2022
Revised: 07 September 2022
Accepted: 14 October 2022
Published: 23 December 2022
© Tsinghua University Press 2022