Research Article

Characteristics of outdoor pollutants intrusion and ventilation control in sentry buildings with normal openings

Linfeng Liang1, Haiguo Yin1,2,3( ), Da Zhang1, Yuekun Han1, Yanyan Li1, Jingying Zhang1, Yongshou Zhang2,3, Zhenjun Ma4, Angui Li1
School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, Shaanxi, China
Qinghai Building and Materials Research Co., Ltd, Xining 810008, Qinghai, China
Qinghai Provincial Key Laboratory of Plateau Green Building and Eco-community, Xining 810008, Qinghai, China
Sustainable Buildings Research Centre, University of Wollongong, Wollongong, NSW 2522, Australia
Show Author Information

Abstract

Sentry buildings have windows that are often open to facilitate communication between personnel. It also provides the possibility for the intrusion of pollutants such as vehicle exhaust emissions. To prevent the intrusion of outdoor pollutants and create an excellent indoor environment, internal circulation with double-attached ventilation (IC-DAV) and external circulation with double-attached ventilation (EC-DAV) are proposed for such buildings, and the isolation effect of two attached ventilation modes on pollutants is compared with that of natural ventilation. A computational fluid dynamics (CFD) method was used to simulate the transportation process and indoor distribution of outdoor pollutants intruding into sentry buildings from the regular openings under different outdoor wind directions, wind velocities, and states of the doors and ventilation modes. The results indicate that the leeward airflow of the three wind directions caused the largest pollutants to invade the room. The amount of pollutants intrusion increased with increasing wind velocity. When the leeward airflow and the windward airflow blow through the building, opening the door increased the amount of pollutants intruding into the room by 3.34 times and 8.85 times, respectively, compared with closing the door. However, the IC-DAV can isolate 81.7% of the pollutants while the EC-DAV can isolate 99.92% of the pollutants as compared with natural ventilation. Applying double attached ventilation mode in buildings can effectively prevent the intrusion of outdoor pollutants into the room, reduce the harm of outdoor pollutants to the health of indoor personnel, and provide a new idea for buildings to improve the indoor air quality.

References

【1】
【1】
 
 
Building Simulation
Pages 393-411

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liang L, Yin H, Zhang D, et al. Characteristics of outdoor pollutants intrusion and ventilation control in sentry buildings with normal openings. Building Simulation, 2023, 16(3): 393-411. https://doi.org/10.1007/s12273-022-0946-4

1085

Views

9

Crossref

6

Web of Science

7

Scopus

0

CSCD

Received: 26 July 2022
Revised: 23 September 2022
Accepted: 26 September 2022
Published: 05 November 2022
© Tsinghua University Press 2022