Research Article

Evaluation of an innovative pediatric isolation (PI) bed using fluid dynamics simulation and aerosol isolation efficacy

Tiantian Liu1Yubing Guo2Xiaotang Hao1Mei Wang1Shicong He2Zhengshi Lin2( )Rong Zhou2( )
School of Public Health, Guangdong Pharmaceutical University, Guangzhou, Guangdong 510310, China
State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, Guangzhou, China
Show Author Information

Abstract

Airborne transmission is an important mechanism of spread for both viruses and bacteria in hospitals, with nosocomial infections putting a great burden on public health. In this study, we designed and manufactured a bed for pediatric clinic consultation rooms providing air isolation to protect patients and medical personnel from pathogen transmission. The pediatric isolation bed has several primary efficiency filters and a high-efficiency particulate air filter in the bedside unit. The air circulation between inlet and outlet forms negative pressure to remove the patient’s exhaled air timeously and effectively. A computational fluid dynamics model was used to calculate the speed of the airflow and the angle of sampler. Following this, we conducted purification experiments using cigarette smoke, Staphylococcus albus (S. albus) and human adenovirus type 5 (HAdV-5) to demonstrate the isolation efficacy. The results showed that the patient’s head should be placed as close to the air inlet hood as possible, and an air intake wind speed of 0.86 m/s was effective. The isolation efficacy of the pediatric isolation bed was demonstrated by computational fluid dynamics technology. The isolation efficiency against cigarette smoke exceeded 91.8%, and against S. albus was greater than 99.8%, while the isolation efficiency against HAdV-5 was 100%. The pediatric isolation bed could be used where isolation wards are unavailable, such as in intensive care units and primary clinical settings, to control hospital acquired infections.

References

【1】
【1】
 
 
Building Simulation
Pages 1543-1552

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu T, Guo Y, Hao X, et al. Evaluation of an innovative pediatric isolation (PI) bed using fluid dynamics simulation and aerosol isolation efficacy. Building Simulation, 2021, 14(5): 1543-1552. https://doi.org/10.1007/s12273-021-0761-3

1337

Views

10

Crossref

9

Web of Science

10

Scopus

0

CSCD

Received: 03 January 2020
Accepted: 21 December 2020
Published: 04 March 2021
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2021