Research Article

Assessing cooling energy reduction potentials by retrofitting traditional cavity walls into passively ventilated cavity walls

Ri Na1( ), Zhigang Shen2
Department of Civil and Environmental Engineering, University of Delaware, Newark, DE 19716, USA
The Durham School of Architecture Engineering and Construction, University of Nebraska Lincoln, Lincoln, NE 68588, USA
Show Author Information

Abstract

A major roadblock in achieving substantial building energy reduction is the low performance of old buildings that account for a significant portion of the building energy consumption. Finding low-cost energy retrofit solutions that do not disrupt occupants’ daily life during the retrofitting is the key to successful building energy retrofit initiatives. In this paper, a novel and low-cost exterior wall retrofitting solution is introduced, and its performance in reducing space cooling load was quantitatively evaluated to demonstrate its feasibility and effectiveness. The primary goal of this paper is to provide a quantitative assessment of the cooling-energy savings potential by using the proposed new wall system. The intended retrofitting targets are the large amount of existing cavity-wall buildings located in hot climate regions. The quantification of the before-after heat-flux reduction was conducted through a 3-dimensional steady-state low turbulence computational fluid dynamics (CFD) model, which is validated by benchmarking its prediction against the published experimental case results. The outcomes of the investigation suggest that this simple low-cost solution has great potentials in reducing buildings’ summer cooling load in hot climate regions. The applicability of this solution is not limited to retrofitting existing buildings. New energy-efficient building designs can also adopt this solution in their envelope systems.

References

【1】
【1】
 
 
Building Simulation
Pages 1295-1309

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Na R, Shen Z. Assessing cooling energy reduction potentials by retrofitting traditional cavity walls into passively ventilated cavity walls. Building Simulation, 2021, 14(4): 1295-1309. https://doi.org/10.1007/s12273-020-0740-0

1165

Views

15

Crossref

N/A

Web of Science

18

Scopus

4

CSCD

Received: 07 July 2020
Accepted: 28 October 2020
Published: 01 December 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020