Investigation of pressure drop in flexible ventilation ducts under different compression ratios and bending angles

Ho Kam Dai1, Wenjie Huang1, Liye Fu2, Chao-Hsin Lin3, Daniel Wei4, Zhongzhe Dong4, Ruoyu You2, Chun Chen1,5( )
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China
Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, China
Environmental Control Systems, Boeing Commercial Airplanes, Everett, WA 98203, USA
Boeing Research & Technology, Beijing 100027, China
Shenzhen Research Institute, The Chinese University of Hong Kong, Shenzhen 518057, China
Show Author Information

Abstract

Due to the large degree of freedom in terms of design and installation, flexible ventilation ducts are commonly used in ventilation systems. However, excessive use of flexible ducts may lead to greater pressure drop and higher energy consumption. This study conducted experimental measurements to characterize the pressure drop in flexible ventilation ducts with different compression ratios and bending angles. This investigation first measured the pressure drop in straight flexible ducts with four compression ratios under various airflow rates. The calculated friction factor for the straight flexible ducts was negatively associated with the compression ratio. Next, the pressure drops in single-bend flexible ducts with various bending angles from 30° to 150° were measured under various airflow rates. The calculated loss coefficient of the bend increased with the bending angle for single-bend flexible ducts. Finally, the influence of the intermediate duct length on the pressure drop across two bends was experimentally investigated. When the length of the intermediate duct was greater than eight times the inner diameter, the pressure drop across a double-bend flexible duct could be calculated from the friction factors and loss coefficients with a relative error less than 1%. The data obtained in this study can be used to calculate the total pressure loss in flexible ventilation ducting systems in buildings.

References

【1】
【1】
 
 
Building Simulation
Pages 1251-1261

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Dai HK, Huang W, Fu L, et al. Investigation of pressure drop in flexible ventilation ducts under different compression ratios and bending angles. Building Simulation, 2021, 14(4): 1251-1261. https://doi.org/10.1007/s12273-020-0737-8

2644

Views

7

Crossref

N/A

Web of Science

7

Scopus

0

CSCD

Received: 17 June 2020
Accepted: 30 September 2020
Published: 12 November 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020