An assessment on the test setups used for energy labeling of ceiling fans

Dilshan Ramesh Casseer, Chathura Ranasinghe( )
Department of Mechanical Engineering, University of Moratuwa, Moratuwa, Sri Lanka
Show Author Information

Abstract

Ceiling fans are used all over the world as a mean of enhancing indoor thermal comfort. A number of grading programs have been initiated for assessing energy performance of ceiling fans, such as ANSI/AMCA 230, Energy Star, IEC 60879, IS 374 and SLS 1600. The configurations of test setups used for performance evaluations in these standards have significant differences to each other. In this study, the influence of such differences on the calculated performance grade of ceiling fans were investigated and the suitability of each dimension of the test set-up is discussed. Particular emphasis was placed on quantifying the effect of the cylindrical drum used in Energy Star and SLS test methods. For this assessment, extensive three-dimensional numerical simulations and experimental measurements were used. Accordingly, the effect of cylinder height, gap between the fan rotation plane and the cylinder, cylinder diameter and the dimensions of the test chamber were investigated. Results show that, the test cylinder, has no significant impact on the calculated performance grade of the tested ceiling fan (variation is less than 2%), and may be eliminated from the test setup. This justifies the recent decision of AMCA on the removal of test cylinder from the fan test set-up. Further, it was also found that the set up dimensions considered herein is large enough so that the calculated start rating is uneffaced by the surrounding solid walls.

Electronic Supplementary Material

Download File(s)
12273_2020_725_MOESM1_ESM.pdf (999.1 KB)

References

【1】
【1】
 
 
Building Simulation
Pages 1175-1188

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Casseer DR, Ranasinghe C. An assessment on the test setups used for energy labeling of ceiling fans. Building Simulation, 2021, 14(4): 1175-1188. https://doi.org/10.1007/s12273-020-0725-z

1139

Views

2

Crossref

N/A

Web of Science

1

Scopus

0

CSCD

Received: 14 February 2020
Accepted: 03 September 2020
Published: 28 November 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020