Research Article

Optimization and sensitivity analysis of design parameters for a ventilation system using phase change materials

Xiaoming Chen1,2Quan Zhang2( )Zhiqiang(John) Zhai3( )Xiaowei Ma2
Key Laboratory of New Energy and Energy-saving in Building, Fujian Province university, and College of Ecological Environment and Urban Construction, Fujian University of Technology, Fujian, Fuzhou 350108, China
College of Civil Engineering, Hunan University, Changsha 410082, China
Department of Civil, Environmental and Architectural Engineering, University of Colorado at Boulder, Boulder, CO 80309, USA
Show Author Information

Abstract

Ventilation system with thermal energy storage (TES) using phase change materials (PCMs) can be employed to save energy in buildings, which stores outdoor coldness in the PCMs at night and releases this energy to cool down the fresh ventilation air during the daytime. However, its performance depends on the design parameters. This paper presents a detailed parametric analysis to address the separate effect of each design parameter on the cooling energy supply and net electricity saving of the TES system against a conventional ventilation system for the climate of Beijing, by using a computational heat transfer model. A genetic algorithm (GA) is used to optimize the design parameters for maximizing the net electricity saving in four cities of China. The decision variables are related to the PCM melting temperature, PCM slab thickness and cold charging airflow rate. The results show that the saving-optimal solution is not unique and depends on the climate. GA optimization increases the net electricity saving by 10%-54%, with a mean value of 31%. Sensitivity analysis of net electricity saving to the above three variables is carried out. Likewise, the sensitivity of each variable is not unique and depends on the climate.

References

【1】
【1】
 
 
Building Simulation
Pages 961-971

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Chen X, Zhang Q, Zhai Z, et al. Optimization and sensitivity analysis of design parameters for a ventilation system using phase change materials. Building Simulation, 2019, 12(6): 961-971. https://doi.org/10.1007/s12273-019-0536-2

1201

Views

9

Crossref

N/A

Web of Science

9

Scopus

0

CSCD

Received: 19 June 2018
Revised: 20 December 2018
Accepted: 12 March 2019
Published: 09 May 2019
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2019