AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Impact of indoor–outdoor temperature differences on dispersion of gaseous pollutant and particles in idealized street canyons with and without viaduct settings

Jian Hang1,2, Riccardo Buccolieri3( ), Xia Yang1, Hongyu Yang1, Francesca Quarta3, Baomin Wang1( )
School of Atmospheric Sciences, Sun Yat-sen University, Guangzhou 510275, China
Guangdong Province Key Laboratory for Climate Change and Natural Disaster Studies, Sun Yat-sen University, Guangzhou 510275, China
Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, University of Salento, S.P. 6 Lecce-Monteroni, 73100 Lecce, Italy
Show Author Information

Abstract

Computational fluid dynamics simulations were performed to investigate flow and pollutant dispersion in a 2D street canyon of aspect ratio H/W = 1. Different from other works, the combination of the presence of viaduct and indoor–outdoor temperature differences ΔT is investigated for different approaching wind velocities. For larger wind velocity (2 m/s, Froude number Fr~3.06–12.24) the typical clockwise vortex leads to higher concentrations of both gas and small particles at the leeward side of the street and in the leeward-side rooms; the vortex is enhanced under large ΔT (20 K) improving the dispersion of pollutants. For smaller velocity (0.5 m/s, Fr~0.19–0.77) the appearance of an anti-clockwise vortex leads to a strong accumulation of gas and particles at the windward side and in the windward-side rooms under low ΔT (5 K); increasing the ΔT raises the dispersion of pollutants with consequent lower concentrations in the rooms (up to an average of 67% with respect to the isothermal case for gaseous pollutants), but accumulation close to the ground level at both windward-side and leeward-side rooms. In the presence of viaduct, together with the main vortex above the viaduct which causes concentrations increasing from low-level to high-level leeward-side rooms, two vortices are generated below it. Still ΔT = 20 K improves the dispersion of pollutants, leading up to a maximum of about 30% lower gaseous concentrations in the rooms. In general, lower concentrations of gas and particles are found for larger velocity, indicating that the mechanical turbulence dominates over the buoyancy effects, which become crucial for smaller velocity. This study confirms previous findings that viaducts may improve pollutant dispersion under large velocity if only one viaduct-level pollutant source exists and indoor–outdoor ΔT conditions can mitigate street air pollution.

References

【1】
【1】
 
 
Building Simulation
Pages 285-297

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Hang J, Buccolieri R, Yang X, et al. Impact of indoor–outdoor temperature differences on dispersion of gaseous pollutant and particles in idealized street canyons with and without viaduct settings. Building Simulation, 2019, 12(2): 285-297. https://doi.org/10.1007/s12273-018-0476-2

1220

Views

37

Crossref

N/A

Web of Science

40

Scopus

4

CSCD

Received: 10 April 2018
Revised: 25 July 2018
Accepted: 10 September 2018
Published: 05 October 2018
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018