Impact of passive climate adaptation measures and building orientation on the energy demand of a detached lightweight semi-portable building

Raffaele Vasaturo1( )Twan van Hooff1,2Ivo Kalkman1Bert Blocken1,2Pieter van Wesemael1
Department of the Built Environment, Eindhoven University of Technology, Eindhoven, the Netherlands
Department of Civil Engineering, KU Leuven, Leuven, Belgium
Show Author Information

Abstract

The building energy demand for heating and cooling is changing due to climate change. The adoption of climate change adaptation measures at the building scale aims at limiting heating and cooling demands. In previous studies on adaptation measures little attention has been paid to lightweight semi-portable buildings, which are increasingly used to temporarily house the growing number of small households (1–2 persons) in peripheral and derelict areas. In this paper the impact of passive climate adaptation measures and building orientation on heating and cooling demands is assessed for a detached, lightweight, semi-portable residential building by means of building energy simulations (BES), considering two climate scenarios for the Netherlands: current climate and a future climate (2050). The results show that the most efficient adaptation measure consists in a combination of exterior solar shading and an increase of thermal resistance of the building envelope, which reduces the annual heating and cooling demand – averaged over eight building orientations – by 11% for the current climate and 15% for the future climate. The impact of building orientation varies according to the climate scenario. Compared to the average over the eight orientations considered, the annual cooling demand for a single orientation varies between about −31% and +22% and between about −24% and +18% for the current and future climate, respectively. For the case without adaptation measures, optimizing the building orientation leads to annual total energy savings of about 4% for the current and 3% for the future climate.

References

【1】
【1】
 
 
Building Simulation
Pages 1163-1177

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Vasaturo R, van Hooff T, Kalkman I, et al. Impact of passive climate adaptation measures and building orientation on the energy demand of a detached lightweight semi-portable building. Building Simulation, 2018, 11(6): 1163-1177. https://doi.org/10.1007/s12273-018-0470-8

1225

Views

49

Downloads

26

Crossref

N/A

Web of Science

26

Scopus

0

CSCD

Received: 16 April 2018
Revised: 23 July 2018
Accepted: 01 August 2018
Published: 30 August 2018
© The Author(s) 2018

This article is published with open access at link.Springer.com

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.