Investigation of operation performance of air carrying energy radiant air-conditioning system based on CFD and thermodynamic model

Jia Liu, Guangcai Gong( ), Riming Liu, Pei Peng
Department of Building Environment and Energy Engineering, College of Civil Engineering, Hunan University, Changsha, Hunan 410082, China
Show Author Information

Abstract

This study aims to investigate the operation performance of a new terminal form of radiant air-conditioning system called the air carrying energy radiant air-conditioning system (ACERS). Three summer operation conditions, namely steady condition (without opening door and window), open-door condition and open-window condition, are researched in a residential apartment using experimental, computational fluid dynamics (CFD) simulation and thermodynamic methods. The concept of dynamic synergistic operation of mechanical ventilation driven by the air-conditioning system and natural ventilation driven by the open door or window is proposed. A thermodynamic model formulated by the dynamic enthalpy equation, dynamic temperature equation and dynamic moisture equation is developed to analyze the heat and mass transfer process of the test room under the synergistic operation of mixing ventilation. Moreover, the CFD simulation results are used to analyze the synergistic operation and thermodynamic energy transfer of the test room under the mixing ventilation of ACERS and open door/window. It is indicated that ACERS is an important technology with a low temperature gradient of less than 0.1 °C between the head (1.5 m) and ankle level (0.1 m) and low velocity of approximately 0.1 m/s in the occupied zone under the steady condition. The thickness of the boundary zone under the orifice plate of ACERS under the steady, open-door and open-window conditions is 12, 6, and 8 cm, respectively, which can effectively prevent condensation. This study proves that ACERS is a promising technology for air conditioning in residential buildings in regions with hot and humid summers.

References

【1】
【1】
 
 
Building Simulation
Pages 1229-1243

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu J, Gong G, Liu R, et al. Investigation of operation performance of air carrying energy radiant air-conditioning system based on CFD and thermodynamic model. Building Simulation, 2018, 11(6): 1229-1243. https://doi.org/10.1007/s12273-018-0454-8

1106

Views

12

Crossref

N/A

Web of Science

13

Scopus

1

CSCD

Received: 25 November 2017
Revised: 16 May 2018
Accepted: 16 May 2018
Published: 05 June 2018
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018