AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Effects of building height and porosity on pedestrian level wind comfort in a high-density urban built environment

Yaxing Du1, Cheuk Ming Mak1( ), Bo-sin Tang2
Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
Department of Urban Planning and Design, University of Hong Kong, Pokfulam, Hong Kong, China
Show Author Information

Abstract

Pedestrian level wind environment is affected by stagnated airflow in high-density cities. This study provides an understanding of the effects of building height and porosity size on pedestrian level wind comfort. The computational fluid dynamics (CFD) technique is utilized to reproduce wind flow around buildings at pedestrian level, and new wind comfort criteria for a low wind environment are adopted to evaluate wind comfort. More specifically, the Steady Reynolds Averaged Navier–Stokes (RANS) renormalization group (RNG) k–ε turbulence model is employed in this study, and the accuracy of the simulation results are assured by validation against the wind tunnel test data. The influence of different building heights and porosity sizes on wind comfort around an isolated building and a group of buildings are subsequently examined. It is shown that an increase building height could improve wind comfort inside the site boundary for both the isolated building and group of buildings. Furthermore, the wind comfort benefits increased when porosity is on the first floor compared to when it is on the second floor. Moreover, larger porosity size generally results in better wind comfort than smaller porosity size. From a practical view point, this study provides information for city planners and architects to use in the improvement of pedestrian level wind comfort, without losing land use efficacy.

References

【1】
【1】
 
 
Building Simulation
Pages 1215-1228

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Du Y, Mak CM, Tang B-s. Effects of building height and porosity on pedestrian level wind comfort in a high-density urban built environment. Building Simulation, 2018, 11(6): 1215-1228. https://doi.org/10.1007/s12273-018-0451-y

1488

Views

65

Crossref

N/A

Web of Science

76

Scopus

3

CSCD

Received: 01 December 2017
Revised: 18 April 2018
Accepted: 23 April 2018
Published: 17 May 2018
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018