AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Potential of perforated exterior louvers to improve the comfort and energy performance of an office space in different climates

Daniel Uribe1,3Waldo Bustamante2,3Sergio Vera1,3( )
Department of Construction Engineering and Management, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
School of Architecture, Pontificia Universidad Católica de Chile, Santiago, Chile
Center for Sustainable Urban Development, Pontificia Universidad Católica de Chile, Santiago, Chile
Show Author Information

Abstract

Fully glazed building façades often experience high solar heat gains and daylight transmission, resulting in high cooling energy consumption and visual discomfort. The objective of this study was to investigate the potential of perforated exterior louvers for controlling solar heat gains through a fenestration system, providing visual comfort to the occupant and improving the energy performance of an office space in distinct climates (tropical, semiarid, humid subtropical, continental) based on integrated thermal and lighting simulations. The louvers evaluated have 0%, 5%, 10%, 15%, 20%, 25% and 30% perforations with 120 and 240 mm louver spacing. This study demonstrates the potential of perforated exterior louvers for controlling solar heat gains and daylight transmission to improve the visual comfort of the occupant and the building energy consumption. Since perforations can significantly influence office performance and occupant comfort, it is crucial for an evaluation of this type of louver to be completed in the early design stages with integrated thermal and lighting simulation tools that are able to address the complex thermal and optical properties of the louvers. Louvers with 120 mm spacing and 5%–20% perforations reduce office energy consumption by 15%–63% (depending on the city) compared with an unshaded window while meeting the visual comfort criteria (sDA300/50% between 96% and 100%, ASE4000/400h of 0% and DGPs perception class A). Additionally, the percentage of perforations and spacing of louvers significantly impact the evaluated performance criteria. CFSs fully cover the window but have evenly distributed perforations outperform shading devices with larger spacing between louvers and louvers without perforations.

References

【1】
【1】
 
 
Building Simulation
Pages 695-708

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Uribe D, Bustamante W, Vera S. Potential of perforated exterior louvers to improve the comfort and energy performance of an office space in different climates. Building Simulation, 2018, 11(4): 695-708. https://doi.org/10.1007/s12273-018-0435-y

1071

Views

23

Crossref

N/A

Web of Science

26

Scopus

0

CSCD

Received: 12 May 2017
Revised: 02 February 2018
Accepted: 05 February 2018
Published: 01 March 2018
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018