AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (466.5 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Numerical investigations of the effects of manikin simplifications on the thermal flow field in indoor spaces

Yihuan Yan1,2Xiangdong Li1Jiyuan Tu1,2( )
School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University, PO Box 71, Bundoora, VIC 3083, Australia
School of Architecture, Tsinghua University, PO Box 2021, Beijing 100084, China
Show Author Information

Abstract

As one of the most basic parameters, manikin body feature could be an important factor influencing the airflow and temperature fields in indoor environments. This study aims to improve the computational efficiency by optimising and simplifying manikin body features. A 3D scanned computer-simulated person (CSP) with extremely detailed body features was employed, followed by two simplified CSP models with different approaches. One of the simplified models was rebuilt based on the skeleton of the 3D scanned model with very limited body features, while the other model was simplified by removing some of the features from the 3D scanned model. All CSPs were tested under quiescent condition, followed by further comparisons under displacement and mixed ventilations. The outcomes indicated that the geometric difference of manikin body would have significant impact on the airflow patterns near manikin bodies, whilst it has very limited influence on the temperature field. The difference of body features could significantly affect the development of thermal plume, which mainly reflected above the manikin head. Also, change of CSP body features due to simplifications may become more sensitive to the predicted results under mixed ventilation, as a result of fewer interactions between the thermal plume and injected airflow.

References

【1】
【1】
 
 
Building Simulation
Pages 219-227

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yan Y, Li X, Tu J. Numerical investigations of the effects of manikin simplifications on the thermal flow field in indoor spaces. Building Simulation, 2017, 10(2): 219-227. https://doi.org/10.1007/s12273-016-0319-y

1087

Views

90

Downloads

15

Crossref

N/A

Web of Science

16

Scopus

0

CSCD

Received: 14 January 2016
Revised: 25 July 2016
Accepted: 03 August 2016
Published: 08 September 2016
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2016