AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Person to person droplets transmission characteristics in unidirectional ventilated protective isolation room: The impact of initial droplet size

Caiqing Yang12Xudong Yang1( )Bin Zhao1
Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Department of Building Science, Tsinghua University, Beijing 100084, China
Beijing Institute of Architectural Design, Beijing 100045, China
Show Author Information

Abstract

Person to person droplets/particles or contaminant cross transmission is an important issue in ventilated environment, especially in the unidirectional ventilated protective isolation room (UVPIR) where the patient’s immune system is extremely low and easily infected. We simulated the dispersion process of the droplets with initial diameter of 100 μm, 10 μm and gaseous contaminant in unidirectional ventilated protective isolation room and studied the droplets dispersion and cross transmission with different sizes. The droplets with initial size of 100 μm settle out of the coughing jet quickly after coming out from mouth and cannot be carried by the coughing jet to the human thermal plume affecting (HTPA) zone of the susceptible manikin. Hence, the larger droplets disperse mainly in the HTPA zone of the source manikin, and the droplets cross transmission between source manikin and susceptible manikin is very small. The droplets with initial size of 10 μm and gaseous contaminant have similar dispersion but different removal process in the UVPIR. Part of the droplets with initial size of 10 μm and gaseous contaminant that are carried by the higher velocity coughing airflow can enter the HTPA zone of the susceptible manikin and disperse around it. The other part cannot spread to the susceptible manikin’s HTPA zone and mainly spread in the source manikin’s HTPA zone. The results from this study would be useful for UVPIR usage and operation in order to minimize the risk of cross infection.

References

【1】
【1】
 
 
Building Simulation
Pages 597-606

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yang C, Yang X, Zhao B. Person to person droplets transmission characteristics in unidirectional ventilated protective isolation room: The impact of initial droplet size. Building Simulation, 2016, 9(5): 597-606. https://doi.org/10.1007/s12273-016-0290-7

1168

Views

35

Crossref

N/A

Web of Science

38

Scopus

7

CSCD

Received: 14 December 2015
Revised: 26 February 2016
Accepted: 23 March 2016
Published: 11 April 2016
>© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2016