Journal Home > Volume 5 , Issue 4

Filters are used in heating, ventilation, and air-conditioning (HVAC) systems for both commercial and residential buildings to protect the equipment and improve indoor air quality in conditioned spaces. Although there are many benefits of using the air filter in an air-conditioning system, the resistance associated with it can increase fan energy use and may adversely affect air-conditioning system performance and efficiency. The paper explores the impact of air filtration on energy consumption for a typical air-conditioning (AC) system with constant- or variable-speed fan. A whole building simulation model is used to simulate the annual energy consumption for various air-conditioning system capacities, different levels of filter cleanliness, and various filter minimum efficiency reporting values (MERV). The results indicate that with a constant-speed fan, the cooling energy use increases as the filter gets dirty over time and the energy use in the fan may increase but this depends heavily on the investigated fan performance curve. With a variable-speed fan, the fan energy use increases with a dirty filter but the cooling and heating energy uses are slightly affected. The fan energy use rise due to the dirty filter depends mainly on air system capacities, filter MERV ratings, and the degree of the filter cleanliness.


menu
Abstract
Full text
Outline
About this article

The impact of air filter pressure drop on the performance of typical air-conditioning systems

Show Author's information Nabil Nassif( )
Department of CAAE Engineering, North Carolina A&T State University, 455 McNair Hall, 1601E. Market Street, Greensboro, NC 27411, USA

Abstract

Filters are used in heating, ventilation, and air-conditioning (HVAC) systems for both commercial and residential buildings to protect the equipment and improve indoor air quality in conditioned spaces. Although there are many benefits of using the air filter in an air-conditioning system, the resistance associated with it can increase fan energy use and may adversely affect air-conditioning system performance and efficiency. The paper explores the impact of air filtration on energy consumption for a typical air-conditioning (AC) system with constant- or variable-speed fan. A whole building simulation model is used to simulate the annual energy consumption for various air-conditioning system capacities, different levels of filter cleanliness, and various filter minimum efficiency reporting values (MERV). The results indicate that with a constant-speed fan, the cooling energy use increases as the filter gets dirty over time and the energy use in the fan may increase but this depends heavily on the investigated fan performance curve. With a variable-speed fan, the fan energy use increases with a dirty filter but the cooling and heating energy uses are slightly affected. The fan energy use rise due to the dirty filter depends mainly on air system capacities, filter MERV ratings, and the degree of the filter cleanliness.

Keywords: HVAC system, air filters, MERV, energy consumptions, fans

References(11)

ANSI/ASHRAE (2007). ANSI/ASHRAE Standard 52.2. Method of testing general ventilation air-cleaning devices for removal efficiency by particle size. Atlanta, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
ASHRAE (2008). ASHRAE Handbook-HVAC Systems and Equipment, Chapters 9 and 28. Atlanta, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
MJ Brandemuehl, S Gabel, I Andersen (1993). A Toolkit for Secondary HVAC System Energy Calculation. Atlanta, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
P James, J Cummings, J Sonne, R Vieira, J Klongerbo (1997). The effect of residential equipment capacity on energy use, demand, and run-time. ASHRAE Transactions, 103(2): 297-303.
N Nassif (2012). Impacts of air filters on energy consumption in typical HVAC systems. Paper presented at the 2012 Annual ASHRAE Meeting, San Antonio, USA.
M Palani, D O'Neal, J Haberl (1992). The effect of reduced evaporator air flow on the performance of a residential central air-conditioner. In: Proceedings of the 8th Annual Symposium on Improving Building Energy Efficiency in Hot and Humid Climates, Dallas, USA.
D Parker, J Sherwin, R Raustad, D Shirey III (1997). Impact of evaporator coil airflow in residential air-conditioning systems. ASHRAE Transactions, 103(2): 395-405.
JA Siegel, WW Nazaroff (2003). Predicting particle deposition on HVAC heat exchangers. Atmospheric Environment, 37: 5587-5596.
B Stephens, A Novoselac, AJ Siegel (2009). Impacts of HVAC Filtration on air-conditioner energy consumption in residences. In: Proceedings of Healthy Buildings 2009 (paper 474), Syracuse, USA.
L Yang, JE Braun, WA Groll (2007a). The impact of evaporator fouling and filtration on the performance of packaged air-conditioners. International Journal of Refrigeration, 30: 506-514.
L Yang, JE Braun, WA Groll (2007b). The impact of fouling on the performance of filter-evaporator combinations. International Journal of Refrigeration, 30: 489-498.
Publication history
Copyright

Publication history

Received: 03 April 2012
Revised: 02 June 2012
Accepted: 19 June 2012
Published: 19 July 2012
Issue date: December 2012

Copyright

© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2012
Return