Case study of window opening behavior using field measurement results

Yiwen Jian( )Yujie GuoJian LiuZhen BaiQingrui Li
College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China
Show Author Information

Abstract

Window opening behavior has significant influences on indoor environment and energy consumption in residential buildings. As a response to indoor environment, the control mechanism (window and interior door open/closed) should be studied first by comprehensive understanding of the variation of indoor environmental conditions. For this reason, a field measurement of environmental conditions was carried out in five representative apartments in Beijing from April to May in 2010. By comparison analyses of the field measurement results, major findings are as follows: (1) the concentration of room CO2 can be the best predictor of occupant behavior, also window opening behavior, in residential buildings; (2) the variation in indoor air quality mainly results from large variation in window opening behavior; (3) apart from indoor and outdoor thermal environment, indoor air quality as well as occupants’ presence at room have also considerable effect on window opening behavior; (4) while defining window opening behavior for one room in residential building, it is necessary to take the window adjustment of its connecting room and the adjustment of the connecting door into consideration due to air diffusion between the two connecting rooms.

References

【1】
【1】
 
 
Building Simulation
Pages 107-116

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Jian Y, Guo Y, Liu J, et al. Case study of window opening behavior using field measurement results. Building Simulation, 2011, 4(2): 107-116. https://doi.org/10.1007/s12273-010-0012-5

1065

Views

35

Crossref

N/A

Web of Science

39

Scopus

0

CSCD

Received: 03 August 2010
Revised: 21 September 2010
Accepted: 26 September 2010
Published: 04 December 2011
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2010