Research Article

Optimization of bathroom ventilation design for an ISO Class 5 clean ward

Caiqing Yang1Xudong Yang1( )Tengfang Xu2Luchun Sun3Wei Gong3
Department of Building Science, School of Architecture, Tsinghua University, Beijing 100084, China
International Energy Studies Group, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS90-3111, Berkeley, CA 94720, USA
Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing 100853, China
Show Author Information

Abstract

Ventilation is a main method to control the contaminant dispersion within clean wards. In this paper, we investigated the effects of various ventilation designs of the bathroom in an ISO Class 5 clean ward. Specifically, the contaminant dispersion and particle concentrations corresponding to three different ventilation design schemes were characterized and compared using computational fluid dynamics (CFD) analysis. For each design, we examined airflow and particle concentrations for contaminant sources located at two places (i.e., at the toilet seat and on the floor), respectively. Field test was conducted to compare the measured and simulated air velocities and particle concentrations in a hospital clean ward. The implemented CFD modeling of ventilation effects of various designs in this study has proven to accurately characterize airflow and contaminant control in the ventilated space, and has led to optimizing ventilation for the bathroom in an ISO Class 5 clean ward.

References

【1】
【1】
 
 
Building Simulation
Pages 133-142

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yang C, Yang X, Xu T, et al. Optimization of bathroom ventilation design for an ISO Class 5 clean ward. Building Simulation, 2009, 2(2): 133-142. https://doi.org/10.1007/s12273-009-9310-1

1528

Views

30

Crossref

N/A

Web of Science

32

Scopus

0

CSCD

Received: 03 April 2009
Revised: 08 May 2009
Accepted: 12 May 2009
Published: 09 June 2009
© Tsinghua University Press and Springer-Verlag 2009