AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Model based evaluation of exterior daylight illuminance distribution

Sheryl G. Colaco1( )Ciji P. Kurian2V. I. George1Anitha M. Colaco3
Department of Instrumentation & Control Engineering, Manipal Institute of Technology, Manipal, India
Electrical & Electronics Engineering, Manipal Institute of Technology, Manipal, India
Electrical & Electronics Engineering, NMAMIT, Nitte, India
Show Author Information

Abstract

Energy conservation in buildings is greatly influenced by natural daylight in tropical region. A vital step towards development and promotion of daylighting technology in buildings is a prior study on estimation of exterior daylight availability for illuminating its interiors. In view of this, the present communication depicts the preliminary work progress carried out to arrive at a comprehensive idea on assessment of daylight availability and its characteristics. The study is reported taking the representative case of Bangalore (India) (latitude 12.97°N, longitude 77.56°E), which in future work facilitates to device suitable interior illuminance models and lighting controls for a daylight-artificial light integrated scheme. The objective of this paper is to document the estimation of spatial exterior daylight parameters like exterior horizontal as well as vertical global and diffuse daylight illuminance in addition to their respective luminous efficacies computed using an established analytical model. The paper also highlights user friendly computer simulation tool developed, for the detailed estimation of daylight availability at a particular region by the inclusion of corresponding solar radiation data.

References

【1】
【1】
 
 
Building Simulation
Pages 85-94

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Colaco SG, Kurian CP, George VI, et al. Model based evaluation of exterior daylight illuminance distribution. Building Simulation, 2009, 2(2): 85-94. https://doi.org/10.1007/s12273-009-9113-4

845

Views

5

Crossref

N/A

Web of Science

5

Scopus

0

CSCD

Received: 02 April 2009
Revised: 27 May 2009
Accepted: 01 June 2009
Published: 09 June 2009
© Tsinghua University Press and Springer-Verlag 2009