AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home iRADIOLOGY Article
PDF (2.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Open Access

Multimodal Comparison of Left Ventricular Function and Volume Assessment Methods in Patients With Coronary Artery Disease: Echocardiography, Nuclear Myocardial Perfusion Imaging, and Cardiac Magnetic Resonance

Fanghu Wang, Xiaochun Zhang, Entao Liu , Xinchao Yao, Zeyin Xiang, Hui Yuan ( ), Lei Jiang ( )
Department of Nuclear Medicine, PET Center, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China

Fanghu Wang and Xiaochun Zhang contributed equally to this work.

Show Author Information

Abstract

Background

To evaluate the correlations and agreement between echocardiography, nuclear myocardial perfusion imaging (MPI), and cardiac magnetic resonance (CMR) for assessing left ventricular (LV) function and volumes in patients with coronary artery disease (CAD).

Methods

Forty‐eight patients with suspected or confirmed CAD who underwent echocardiography, nuclear MPI, and CMR within 1 week were included. The LV ejection fractions (EF), end‐diastolic volume (EDV), and end‐systolic volume (ESV) obtained using each modality were compared using correlational and Bland–Altman analyses, with CMR serving as the reference standard. Additionally, 13N‐NH3 and 99mTc‐sestamibi (99mTc‐MIBI) MPI subgroup analyses were conducted using CMR as the reference.

Results

Nuclear MPI showed better correlation and agreement with CMR than echocardiography for EF values (r = 0.93 vs. 0.88; bias: −2.8% vs. 4.4%). For LV volumes, nuclear MPI and CMR showed excellent correlations (EDV/ESV: r = 0.94) with better ESV agreement (bias: −10.1 mL) than EDV (−25.4 mL). In subgroup analyses, 13N‐NH3 PET MPI maintained excellent correlations with CMR (EF: r = 0.95; EDV/ESV: r = 0.97), with minimal EF bias (−0.7%). 99mTc‐MIBI SPECT MPI showed a greater EF bias (−7.8%) despite a good correlation (r = 0.95) and wider limits of agreement for LV volumes (EDV: −92.3 to 47.4 mL; ESV: −66.0 to 61.7 mL).

Conclusions

13N‐NH3 PET MPI demonstrates excellent correlation and agreement with CMR, providing a reliable alternative for assessing LV function and volumes in patients with CAD. Contrarily, echocardiography systematically overestimates EFs. These findings provide practical insights into discrepancies among imaging modalities and may support clinical decision‐making in CAD management.

Graphical Abstract

References

【1】
【1】
 
 
iRADIOLOGY
Pages 401-411

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang F, Zhang X, Liu E, et al. Multimodal Comparison of Left Ventricular Function and Volume Assessment Methods in Patients With Coronary Artery Disease: Echocardiography, Nuclear Myocardial Perfusion Imaging, and Cardiac Magnetic Resonance. iRADIOLOGY, 2026, 4(5): 401-411. https://doi.org/10.1002/ird3.70101

5

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 22 July 2025
Revised: 31 May 2026
Accepted: 24 June 2026
Published: 12 October 2026
© 2026 The Author(s). Tsinghua University Press.

This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.