AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (9.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Biomechanical research of combined fixation with multiple locking plate osteosynthesis for hyperextension tibial plateau fractures

Xiang Yao1,2, Weijie Pan2, Zheng Zhong2, Yong Xu1 ( )
Department of Orthopaedics, the Affiliated People’s Hospital of Jiangsu University, Zhenjiang 212000
School of Medicine, Jiangsu University, Zhenjiang 212013, China
Show Author Information

Abstract

Objective

To evaluate the differences in biomechanical performance of using multiple locking plate osteosynthesis for hyperextension tibial plateau fracture (HTPF).

Methods

HTPF models were constructed using standardized artificial biomimetic tibia. Six plate fixation schemas were assembled: anterolateral, anteromedial, anterolateral + anteromedial, anteromedial + posteromedial, anterolateral+posteromedial, and tri-plate schema. Nine models were subjected to longitudinal loads of 250, 500, 1000, and 1500 N applied to the superior surface of the tibial plateau. The comprehensive displacement for each fixation schema was calculated using a three-dimensional camera system. Nine models were subjected to a uniform rotation of the proximal bone segment at a constant angular velocity of 0.5°/s. The torque required to achieve 10° of internal rotation and 10° of external rotation was recorded for each fixation schema. A repeated-measures analysis of variance was employed to assess the effects of fixation modality, compression (rotation), and their interaction on internal fixation outcomes. Pairwise comparisons were performed via paired t-tests, with multiple comparison adjustments implemented using the Bonferroni correction. Additionally, the paired standardized effect size (Cohen’s d) and its 95% confidence interval were calculated.

Results

The axial load tests revealed that the greater the applied pressure, the larger the overall displacement. When the axial load was 1500 N, the comprehensive displacement values of the groups of fixation schemas were as follows: anterolateral (5.16 ± 2.39) mm>anteromedial (4.04 ± 1.40) mm>anterolateral + anteromedial (2.56 ± 0.57) mm>anteromedial + posteromedial (1.75±0.71) mm>anterolateral+posteromedial (0.70±0.27) mm>tri-plate schema (0.34±0.10) mm. The horizontal rotation tests revealed that the average torque for a ±10° rotation was as follows: anterolateral (9.87±2.07) N·m<anteromedial (10.61±1.91) N·m<anteromedial+posteromedial (24.72±4.75) N·m<anterolateral+anteromedial (27.61±3.06) N·m<anterolateral+posteromedial (32.81± 6.62) N·m<tri-plate schema (43.95±8.23) N·m. At a load of 1500 N, within the dual-plate fixation schemas, the comprehensive displacement values of Groups 3 and 4 were significantly higher than that of Group 5(P < 0.05). For the average torque, within the dual-plate fixation schemas, no significant differences in torque were detected between Group 3 and Group 4, or between Group 3 and Group 5(P > 0.05); by contrast, the torque value of Group 5 was significantly higher than that of Group 4(P < 0.05).

Conclusion

For HTPF with intact articular surfaces, the fixation efficacy of locking plates increases with the number of plates used. Under the model and loading conditionsof this study, the dual-plate schema combining anterolateral and posteromedial plates exhibited smaller displacement and numerically higher torsional resistance, indicating a potential advantage in fixation performance.

CLC number: R681.8 Document code: A Article ID: 1007-4368(2026)11-1704-11

References

【1】
【1】
 
 
Journal of Nanjing Medical University (Natural Sciences)
Pages 1704-1713

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Yao X, Pan W, Zhong Z, et al. Biomechanical research of combined fixation with multiple locking plate osteosynthesis for hyperextension tibial plateau fractures. Journal of Nanjing Medical University (Natural Sciences), 2026, 46(11): 1704-1713. https://doi.org/10.7655/NYDXBNSN260856

1

Views

0

Downloads

0

Crossref

Received: 07 July 2026
Revised: 28 September 2026
Accepted: 08 October 2026
Published: 15 November 2026
© 2026 Editorial Board of Journal of Nanjing Medical University(Natural Sciences)

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).