AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Application of non-axisymmetric endwall contouring in compressor intermediate duct with a large radius change to length ratio

Xiaochen MAO1,2( ), Min LI1,2, Limin GAO1,2, Yu WU1,2
School of Power and Energy, Northwestern Polytechnical University, Xi'an 710072, China
National Key Laboratory of Aerodynamic Design and Research, Northwestern Polytechnical University, Xi'an 710072, China
Show Author Information

Abstract

In order to explore the application potential of non-axisymmetric endwall contouring in the compressor intermediate duct with a large radius change to length ratio, the aerodynamic characteristic of this type of compressor intermediate duct has been numerically studied in the present work, and the effect of the non-axisymmetric endwall contouring on the hub of the compressor intermediate duct has been investigated in terms of flow and throttle characteristics. The results show that, the flow loss and outlet flow distortion of the compressor intermediate duct are mainly originated from the corner separation of the strut. With the increase of the flow rate, the flow loss and outlet flow distortion are enhanced, which is opposite to the change of the strut corner separation. On this basis, this study has proposed a novel approach for non-axisymmetric endwall contouring using trigonometric functions. By adjusting the curvature of the hub contour near the strut and modifying the axial pressure gradient, this method can effectively reduce the intensity of the corner separation around the strut. Moreover, the implementation of such a non-axisymmetric endwall contouring does not compromise the decreasing trend of the total pressure recovery coefficient with increasing flow rate. Within a wide range of large flow rates (with the relative flow rate not lower than 0.6) in the compressor intermediate duct, this method can successfully attenuate the intensity of secondary flows within the compressor intermediate duct, and reduce the total pressure loss coefficient of the intermediate duct by about 6.4%.

CLC number: V232 Document code: A

References

【1】
【1】
 
 
Acta Aerodynamica Sinica
Pages 33-42

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
MAO X, LI M, GAO L, et al. Application of non-axisymmetric endwall contouring in compressor intermediate duct with a large radius change to length ratio. Acta Aerodynamica Sinica, 2024, 42(11): 33-42. https://doi.org/10.7638/kqdlxxb-2023.0165

626

Views

9

Downloads

0

Crossref

1

Scopus

0

CSCD

Received: 21 September 2023
Revised: 30 October 2023
Published: 01 August 2024
© The journal of Acta Aerodynamica Sinica.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).