AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (14.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Multi-spectral measurement method for high-temperature surface temperature field through emissivity pre-recognition and White Shark optimization algorithm

Zhengjun ZHANG1, Yizhi HUANG1, Yan LIU2, Biao ZHANG1, Xiang XU2, Chuanlong XU1( )
National Engineering Research Center of Power Generation Control and Safety, School of Energy and Environment, Southeast University, Nanjing 210096, China
Institute of Engineering Thermophtsics, Chinese Academy of Sciences, Beijing 100190, China
Show Author Information

Abstract

Multispectral thermometer is widely used for temperature measurement of high temperature components in gas turbines such as turbine blades and combustion chambers. However, without the prior emissivity information of the measured target, the multi-spectral thermometer often results in large measurement error, which limits its practical application. In this paper, a multi-spectrum radiation-based temperature inversion method integrating emissivity pre-recognition is proposed. This method transforms the underdetermined radiation equations into a constrained optimization problem of the objective function. Based on the grey body hypothesis and generalized inverse matrix method, the range of emissivity is firstly obtained and added to the objective function as a constraint. The White Shark optimization algorithm is further used to achieve the high-precision temperature solution of the constrained objective function. The key parameters and reconstruction performance of the proposed algorithm are discussed on the six simulated emissivity models at different temperatures. The simulation results showed that the maximum error of the temperature inversion is 1.95% at 800-1 000 K. Finally, the temperature measurement experiments are carried out on a high temperature surface in the lab. The maximum deviation of the measured temperature between the proposed method and the thermocouple is 2.01%, verifying that the proposed multi-spectral measurement method has high accuracy and stability.

CLC number: V4.9;TH811 Document code: A Article ID: 1000-6893(2025)16-131662-14

References

【1】
【1】
 
 
Acta Aeronautica et Astronautica Sinica

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG Z, HUANG Y, LIU Y, et al. Multi-spectral measurement method for high-temperature surface temperature field through emissivity pre-recognition and White Shark optimization algorithm. Acta Aeronautica et Astronautica Sinica, 2025, 46(16). https://doi.org/10.7527/S1000-6893.2025.31662

966

Views

10

Downloads

0

Crossref

1

Scopus

0

CSCD

Received: 13 December 2024
Revised: 12 February 2025
Accepted: 04 March 2025
Published: 07 March 2025
© 2025 The Journal of Acta Aeronautica et Astronautica Sinica