AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (3.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Establishment and Application of a Duplex Droplet Digital Polymerase Chain Reaction Assay for the Detection of Genetically Modified Maize CC-2

Yuxuan HE Wei YANNing ZHAOZhenjuan XINGLiming DONGYue MAFan YANGLikun LONG ( )Feiwu LI ( )
Institute of Agricultural Quality Standards and Testing Technology, Jilin Academy of Agricultural Sciences (Northeast Agricultural Research Center of China), Changchun 130033, China
Show Author Information

Abstract

This study aimed to establish a highly specific and sensitive quantitative assay for transgenic maize CC-2, independently developed in China, using droplet digital polymerase chain reaction (ddPCR). Primers and probes were designed to target the specific insertion sequence of the CC-2 event. The reaction conditions were systematically optimized. A duplex ddPCR system was successfully developed, enabling the simultaneous detection of the endogenous gene and the CC-2 event-specific fragment. The verification results demonstrated that this method exhibited no cross-amplification in various non-target genetically modified (GM) events, confirming its high specificity; a linear response was achieved covering the range from 20 to 20000 copies for the genomic DNA of CC-2, and the limit of detection (LOD) and limit of quantification (LOQ) were found to be 10 and 20 copies, respectively. In a blind test, the method demonstrated high repeatability and accuracy for samples containing varying concentrations of the event, meeting both national and international standards for the quantitative analysis of genetically modified organisms (GMO). The ddPCR method provides a robust technical foundation for the commercial cultivation of transgenic maize CC-2 and the regulatory monitoring of its products.

CLC number: S513 Document code: A Article ID: 1002-6630(2025)24-0285-08

References

【1】
【1】
 
 
Food Science
Pages 285-292

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HE Y, YAN W, ZHAO N, et al. Establishment and Application of a Duplex Droplet Digital Polymerase Chain Reaction Assay for the Detection of Genetically Modified Maize CC-2. Food Science, 2025, 46(24): 285-292. https://doi.org/10.7506/spkx1002-6630-20250619-139

64

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 19 June 2025
Published: 25 December 2025
© Beijing Academy of Food Sciences 2025.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).