AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (5.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Accurate Quantification of Escherichia coli O157 in Grape Juice Using Hydrogel-Based Digital Polymerase Chain Reaction

College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
Binjiang Institute of Zhejiang University, Hangzhou 310058, China
Show Author Information

Abstract

In this study, we developed a direct hydrogel digital polymerase chain reaction (Direct-hdPCR) technique for the detection of Escherichia coli O157 in grape juice. In this method, samples were directly mixed with a hydrogel PCR system, followed by release of bacterial DNA through thermal lysis, and in situ digital PCR amplification of target DNA was achieved by taking advantage of the three-dimensional network structure of the hydrogel material. The amplified products were visualized as fluorescent dots, whose number of dots corresponded to the number of DNA molecules, enabling precise quantitative analysis. PCR primers specific to E. coli O157 were designed, and the developed method was validated for feasibility, sensitivity and specificity and was applied to real samples. The results demonstrated that this method exhibited high sensitivity, with a detection limit as low as the single bacterium level, without any need for DNA extraction or purification. It also showed strong specificity to the target bacterium and excellent anti-inhibition effects, without any need for sample pretreatment. The total detection time, from sample preparation to result reporting, was reduced to less than 40 minutes. Using the Direct-hdPCR method, all contaminated grape juice samples were directly detected with a positive detection rate of 100%, which is consistent with the results obtained by the dilution plating method. The average recoveries ranged from 96.9% to 112.0%, with a relative standard deviation (RSD) of 3.6% to 12.4%. This method offers advantages such as rapidity, high sensitivity, no need for sample pretreatment, and simple operation, making it suitable for on-site testing.

CLC number: TS207.4 Document code: A Article ID: 1002-6630(2025)15-0001-09

References

【1】
【1】
 
 
Food Science
Pages 1-9

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YI Z, LIN X. Accurate Quantification of Escherichia coli O157 in Grape Juice Using Hydrogel-Based Digital Polymerase Chain Reaction. Food Science, 2025, 46(15): 1-9. https://doi.org/10.7506/spkx1002-6630-20250103-015

486

Views

6

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 03 January 2025
Published: 15 August 2025
© Beijing Academy of Food Sciences 2025.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).